P/N 18982-008 Rev A FLOW Service Guide
8
5. Replacing Dongles in AMRs
Step
Check Item
Task to be Performed
Check
1
Download
Debug info and
check for
installed
advanced
features
Follow the procedure in the LD service manual (18745-000) section 1-1 (Download the file)
and section 1-2 (Download the Debug info file). This will backup the system in case of
AMR core failure. In SNG, under the Licensing tab, check if there are any advanced
feature packs installed. If there are any advanced feature packs record the License # to be
sent along with the C2V file.
□
2
Remove the LD
core
Follow steps 1-8 in LD service manual (18745-000) section 2-2-1. Replacing the LD core
□
3
Install dongle
Remove failed dongle and install new dongle/s.
Note:
Position of dongles is not important.
□
4
Enable
entitlement
If installing advanced feature software follow the procedure in the FLOW CORE User
’
s
Guide section 7.6(Licensing Tab) for enabling entitlement.
□