F3UV

F3UV

16

J

PRECAUTIONS FOR THE

F3UV-XW11/XW41

Installation

1. Installation Torque

Torque the sensor’s Main Unit screws to 0.49 N-m (0.36 ft lbs)
max.

2. Using DIN Track: Installation

A. Hook the top of the Unit onto the DIN Track.
B. Snap the bottom of the Unit onto the DIN Track.

Note:

Do not reverse steps A and B.

Removal

When removing the Unit from the DIN Track, pull the mounting

hooksforward to release it.

DIN

Track

Mounting hook

(2)

(1)

J

PRECAUTIONS REGARDING UV LIGHT

The Amplifier itself is not protected against UV exposure. Do not

install the Amplifier in locations where it will be exposed to UV

light.

J

OPERATION AND ADJUSTMENT

1. Install the Amplifier Unit.
2. Connect the Fiber Unit to the Amplifier Unit.
3. Turn ON the power supply.
4. Select an operating mode with the operation mode switch.

(Light intensity monitor mode or light intensity integral

mode)

5. When using the analog output, select current or voltage

output with the output selection switch.

6. Set the processing mode switch to TEACH and perform the

teaching operation.

·

Light Intensity Monitor Mode

Make the zero-point setting when the indicator is not lit

and make the sensitivity setting when the indicator is lit.

(Make the sensitivity setting after the temperature has

stabilized.)

·

Light Intensity Integral Mode

Use the start setting at the start of illumination and the

stop setting when completed. Teaching can be performed

by pressing the buttons or with codes.

7. When changing the threshold value in light intensity

monitor mode, set the processing mode switch to ADJ and

adjust the threshold value. The judgement output will go

ON when the light intensity is below the threshold value.

The threshold value is set to 50 at the factory.

8. Set the processing mode switch to RUN to start

measurement. In light intensity integral mode, start

integration with the Reset input.

J

CLEANING

Never use paint thinner or mineral spirits of any kind.

Summary of Contents for F3UV Series

Page 1: ...structure H Confirm the output status of the UV light source with an operation indicator H Filtering Cover also available reduces light intensity by 1 6 5 Ordering Information J MONITORS WITH BUILT IN...

Page 2: ...W cm2 1 F32 70 Note The values given are for a standard UV light source with a central wavelength of 360 nm measured with a standard illumination meter and for use in combination with the specified Am...

Page 3: ...Ambient humidity Operating 35 to 85 Insulation resistance 20 MW min at 500 VDC Dielectric strength 1 000 VAC 50 60 Hz for 1 min Vibration resistance 10 to 150 Hz 0 1 mm amplitude in X Y and Z directio...

Page 4: ...aterial Head connector Nickel plated brass End cap Tube Stainless SUS304 Attachment M2 screws Protective Tube Protects the Fiber Item F39 FU1M Item 1 m Head connector Flexible tube End cap Ambient tem...

Page 5: ...n the leads and the case Vibration resistance 10 to 150 Hz 0 1 mm amplitude or 15 m s2 in X Y and Z directions each for 2 hours Shock resistance 150 m s2 three times each in the X Y and Z directions D...

Page 6: ...The maximum temperature is lower near the amplifier unit See the Dimensions for details Engineering Data J MONITORS WITH BUILT IN AMPLIFIERS Output Characteristics F3UV A30 Output characteristics whe...

Page 7: ...odels Intensity relative Wavelength nm Nomenclature J MONITORS WITH BUILT IN AMPLIFIERS F3UV A30 A03 Operation indicator orange Power indicator green Sensitivity adjuster VR Functions Name Function Di...

Page 8: ...ustment Down button Light intensity integral mode ITG TEACH Start integration Measurement Teaching indicator Illuminated green Teaching OK RUN Flashing red Teaching error Illuminated red Start light i...

Page 9: ...is in monitor mode or integral mode teaching is performed when a pulse signal is input here Threshold setting function monitor mode only The desired threshold value can be set by pressing the Up and...

Page 10: ...put 0 V Gray Internal circuit F3UV XW11 NPN Output Purple Pink Blue White Main circuit Black Blue Output 1 to 5 V 0 V Sensitivity adjuster Measurement teaching green red Operation orange Display Reset...

Page 11: ...8 2000 78 74 J ACCESSORIES SOLD SEPARATELY Protective Tube Protects Cord F39 CU1M End Cap Note 1 5 dia 0 20 Two M2 7 dia Tube Note 2 Head Connector Note 1 15 dia 7 dia Tube internal diameter 5 Hex he...

Page 12: ...6 05 1 42 14 0 55 0 2 0 01 0 55 0 02 2 0 08 12 2 0 48 32 5 1 28 2 6 0 10 6 9 0 27 13 75 0 54 12 6 0 50 32 5 1 28 35 5 1 40 17 1 0 67 19 8 0 78 17 0 67 19 8 0 78 17 3 0 68 2 8 0 11 17 0 67 20 0 1 0 79...

Page 13: ...up button Monitor Integral mode switch Current Voltage output switch 7 segment display Fiber lock button Vinyl insulated round cable 5 8 dia 7 conductors Conductor cross sectional area 0 2 mm2 diamet...

Page 14: ...ial Stainless steel SUS303 Material Stainless steel SUS303 1 dia 0 04 M2 6 0 45 Hex nuts 2 Lock washers 2 Detection head M4 0 7 Optical fiber 2 2 dia Material Nickel plated brass 7 0 28 20 0 79 2 4 0...

Page 15: ...e sensor s display and cord are not protected against UV ex posure If these parts will be exposed to UV light protect them with the F39 HU2 Protective Cover and F39 CU1M Protective Tube When UV light...

Page 16: ...al mode 5 When using the analog output select current or voltage output with the output selection switch 6 Set the processing mode switch to TEACH and perform the teaching operation Light Intensity Mo...

Page 17: ...surface may not be clean enough and the detection characteristics may be degraded 2 Installing the Fiber With the lock button in the release position insert the fiber into the Unit and press the butto...

Page 18: ...F3UV F3UV 18 J APPLICATION EXAMPLES...

Page 19: ...24 22 0 317 0 644 0 025 21 0 397 0 723 0 028 20 0 519 0 812 0 032 19 0 657 0 912 0 036 18 0 811 1 024 0 040 17 1 025 1 15 0 045 16 1 32 1 29 0 051 15 1 65 1 45 0 057 14 2 08 1 63 0 064 13 2 63 1 83 0...

Page 20: ...eters to inches divide by 25 4 OMRON CANADA INC 885 Milner Avenue Scarborough Ontario M1B 5V8 416 286 6465 R Cat No E315 E3 1 10 00 Specifications subject to change without notice Printed in U S A OMR...

Reviews: