PRECAUTIONS FOR THE
F3UV-XW11/XW41
Installation
1. Installation Torque
Torque the sensor’s Main Unit screws to 0.49 N-m (0.36 ft lbs)
max.
2. Using DIN Track: Installation
A. Hook the top of the Unit onto the DIN Track.
B. Snap the bottom of the Unit onto the DIN Track.
Note:
Do not reverse steps A and B.
Removal
When removing the Unit from the DIN Track, pull the mounting
hooksforward to release it.
DIN
Track
Mounting hook
(2)
(1)
J
PRECAUTIONS REGARDING UV LIGHT
The Amplifier itself is not protected against UV exposure. Do not
install the Amplifier in locations where it will be exposed to UV
light.
J
OPERATION AND ADJUSTMENT
1. Install the Amplifier Unit.
2. Connect the Fiber Unit to the Amplifier Unit.
3. Turn ON the power supply.
4. Select an operating mode with the operation mode switch.
(Light intensity monitor mode or light intensity integral
mode)
5. When using the analog output, select current or voltage
output with the output selection switch.
6. Set the processing mode switch to TEACH and perform the
teaching operation.
·
Light Intensity Monitor Mode
Make the zero-point setting when the indicator is not lit
and make the sensitivity setting when the indicator is lit.
(Make the sensitivity setting after the temperature has
stabilized.)
·
Light Intensity Integral Mode
Use the start setting at the start of illumination and the
stop setting when completed. Teaching can be performed
by pressing the buttons or with codes.
7. When changing the threshold value in light intensity
monitor mode, set the processing mode switch to ADJ and
adjust the threshold value. The judgement output will go
ON when the light intensity is below the threshold value.
The threshold value is set to 50 at the factory.
8. Set the processing mode switch to RUN to start
measurement. In light intensity integral mode, start
integration with the Reset input.
J
CLEANING
Never use paint thinner or mineral spirits of any kind.