Specifications

J

RATINGS/CHARACTERISTICS

Monitors with Built-in Amplifiers (Main Unit)

Item

F3UV-A30

F3UV-A03

Incident light power range

(See Note 1)

1 to 30 mW/cm

2

0.2 to 3 mW/cm

2

Incident light wavelength range

200 to 370 nm

Power indicator

Green LED

Operation indicator

Orange LED (lights with an output between 4 and 5 V)

Sensitivity adjustment

One-turn potentiometer

Power supply voltage

12 to 24 VDC

±

10%

Current consumption

15 mA max.

Response time (See Note 2)

300 ms max.

400 ms max.

Output (See Note 3)

1 to 5 V (with an offset voltage of 0.2 V min.)

Connection impedance

100 k

W

min.

Repeatability

±

2% Full Scale max.

Temperature drift

0.2% of Full Scale/

°

C max.

Ambient operating illumination

(See Note 4)

Fluorescent light 1,000 lux max.

Fluorescent light 500 lux max.

Ambient temperature

Operating: --10

°

to 70

°

C (14

°

to 158

°

F) Storage: --25

°

to 80

°

C (--13

°

to 176

°

F)

Ambient humidity

Operating: 35% to 85%

Insulation resistance

20 M

W

min. (at 500 VDC)

Dielectric strength

1,000 VAC 50/60 Hz for 1 min

Vibration resistance

10 to 150 Hz, 0.1-mm amplitude in X, Y, and Z directions

(8 minutes of vibration

´

10 repetitions= total time of 80 minutes)

Shock resistance

150 m/s

2

three times each in the

±

X,

±

Y, and

±

Z directions approximately 1.5 G

Degree of protection

Conforms to IEC IP30

Connection method

Pre-wired cable with a standard length of 2 m

Weight (packed)

78 g (2.75 oz)

Material

Casing: die-cast zinc

Window: synthetic quartz glass

Accessories

Operation Manual

Note: 1.

Using a standard UV light source and UV illumination meter in a power range for which analog output can be set to 5 V.

2.

The response time is the rise time of the output signal.

3.

An output voltage up to 6 V can be output. Adjust the sensitivity so that the output is less than 5 V. The output is 0.2 to 1 V
when there is no incident UV light.

4.

This value is the illumination at the receiver window maintaining an offset voltage of 1 V max. with the fluorescent light.

Summary of Contents for F3UV Series

Page 1: ...structure H Confirm the output status of the UV light source with an operation indicator H Filtering Cover also available reduces light intensity by 1 6 5 Ordering Information J MONITORS WITH BUILT IN...

Page 2: ...W cm2 1 F32 70 Note The values given are for a standard UV light source with a central wavelength of 360 nm measured with a standard illumination meter and for use in combination with the specified Am...

Page 3: ...Ambient humidity Operating 35 to 85 Insulation resistance 20 MW min at 500 VDC Dielectric strength 1 000 VAC 50 60 Hz for 1 min Vibration resistance 10 to 150 Hz 0 1 mm amplitude in X Y and Z directio...

Page 4: ...aterial Head connector Nickel plated brass End cap Tube Stainless SUS304 Attachment M2 screws Protective Tube Protects the Fiber Item F39 FU1M Item 1 m Head connector Flexible tube End cap Ambient tem...

Page 5: ...n the leads and the case Vibration resistance 10 to 150 Hz 0 1 mm amplitude or 15 m s2 in X Y and Z directions each for 2 hours Shock resistance 150 m s2 three times each in the X Y and Z directions D...

Page 6: ...The maximum temperature is lower near the amplifier unit See the Dimensions for details Engineering Data J MONITORS WITH BUILT IN AMPLIFIERS Output Characteristics F3UV A30 Output characteristics whe...

Page 7: ...odels Intensity relative Wavelength nm Nomenclature J MONITORS WITH BUILT IN AMPLIFIERS F3UV A30 A03 Operation indicator orange Power indicator green Sensitivity adjuster VR Functions Name Function Di...

Page 8: ...ustment Down button Light intensity integral mode ITG TEACH Start integration Measurement Teaching indicator Illuminated green Teaching OK RUN Flashing red Teaching error Illuminated red Start light i...

Page 9: ...is in monitor mode or integral mode teaching is performed when a pulse signal is input here Threshold setting function monitor mode only The desired threshold value can be set by pressing the Up and...

Page 10: ...put 0 V Gray Internal circuit F3UV XW11 NPN Output Purple Pink Blue White Main circuit Black Blue Output 1 to 5 V 0 V Sensitivity adjuster Measurement teaching green red Operation orange Display Reset...

Page 11: ...8 2000 78 74 J ACCESSORIES SOLD SEPARATELY Protective Tube Protects Cord F39 CU1M End Cap Note 1 5 dia 0 20 Two M2 7 dia Tube Note 2 Head Connector Note 1 15 dia 7 dia Tube internal diameter 5 Hex he...

Page 12: ...6 05 1 42 14 0 55 0 2 0 01 0 55 0 02 2 0 08 12 2 0 48 32 5 1 28 2 6 0 10 6 9 0 27 13 75 0 54 12 6 0 50 32 5 1 28 35 5 1 40 17 1 0 67 19 8 0 78 17 0 67 19 8 0 78 17 3 0 68 2 8 0 11 17 0 67 20 0 1 0 79...

Page 13: ...up button Monitor Integral mode switch Current Voltage output switch 7 segment display Fiber lock button Vinyl insulated round cable 5 8 dia 7 conductors Conductor cross sectional area 0 2 mm2 diamet...

Page 14: ...ial Stainless steel SUS303 Material Stainless steel SUS303 1 dia 0 04 M2 6 0 45 Hex nuts 2 Lock washers 2 Detection head M4 0 7 Optical fiber 2 2 dia Material Nickel plated brass 7 0 28 20 0 79 2 4 0...

Page 15: ...e sensor s display and cord are not protected against UV ex posure If these parts will be exposed to UV light protect them with the F39 HU2 Protective Cover and F39 CU1M Protective Tube When UV light...

Page 16: ...al mode 5 When using the analog output select current or voltage output with the output selection switch 6 Set the processing mode switch to TEACH and perform the teaching operation Light Intensity Mo...

Page 17: ...surface may not be clean enough and the detection characteristics may be degraded 2 Installing the Fiber With the lock button in the release position insert the fiber into the Unit and press the butto...

Page 18: ...F3UV F3UV 18 J APPLICATION EXAMPLES...

Page 19: ...24 22 0 317 0 644 0 025 21 0 397 0 723 0 028 20 0 519 0 812 0 032 19 0 657 0 912 0 036 18 0 811 1 024 0 040 17 1 025 1 15 0 045 16 1 32 1 29 0 051 15 1 65 1 45 0 057 14 2 08 1 63 0 064 13 2 63 1 83 0...

Page 20: ...eters to inches divide by 25 4 OMRON CANADA INC 885 Milner Avenue Scarborough Ontario M1B 5V8 416 286 6465 R Cat No E315 E3 1 10 00 Specifications subject to change without notice Printed in U S A OMR...

Reviews: