![background image](http://html1.mh-extra.com/html/omron/f3ss/f3ss_instruction-manual_1633198012.webp)
4-5 Switch Settings
4 Installation
8
Figure 4-1 Installation Example Using Mirrors
4-5 Switch Settings
4-5-1 Emitter and Receiver Code Switches
Both the emitter and the receiver must be set to the same code. Switch settings other than those given below
will result in a fault condition.
4-5-2 Operating Mode Switches
Operating modes are described on page “Receiver Operating Mode Switch” on page 5. Positions 1 & 2 on SW1
and SW2 in the receiver are used to set the operation mode. Switch settings are given below:
Code #
Emitter Dip Switch
Receiver Dip Switch Position
Position (SW1)
(SW1)
(SW2)
2
3
4
3
4
3
4
A
OFF
OFF
OFF
OFF
OFF
OFF
OFF
B
OFF
ON
ON
ON
OFF
ON
OFF
C
ON
OFF
ON
OFF
ON
OFF
ON
D
ON
ON
OFF
ON
ON
ON
ON
Receiver DIP Switch Position (SW1 & SW2)
Operating Mode
1
2
Automatic Start
ON
ON
Start Interlock
OFF
ON
Not Valid
ON
OFF
Start/Restart Interlock
OFF
OFF
Emitter
Receiver
Floor
900 mm
(36 in)
400 mm
(16 in)
Mirrors
Summary of Contents for F3SS