4-7 Machine Control Circuit Connections
4 Installation
16
Figure 4-8 Connection Method(Example of connection to Type G9SA-301 Safety Relay Unit [also applicable to category 4])
TH
SA
E1
E2
Emitter
Receiver
Control output 1(+) [1]
Control output 2(+) [3]
COM for control output 1/2(-) [2]
Feedback loop
Model F3SS
Light ON
Blocked
Reset switch S1
Contacts K1 & K2 a
Contacts K1 & K2 b
Contacts KM1 & KM2 a
Contacts KM1 & KM2 b
PLC input
PLC output
KM3
Description in square parentheses indicates terminal name
or terminal number.
S1:Reset switch (NO contact)
KM1 and KM2:Magnet contactor (model LP1D)
KM3:Solid-state contactor (model G3J)
M:3-phase motor
E1 and E2:24VDC power supply (model S82K)
Note: When connecting the F3SS and G9SA-301 models, do not use the start/restart interlock function incorporated in the F3SS model, only use the
interlock function incorporated in the G9SA-301 model.
Operation Chart
Example of connection to Type G9SA-301 Safety Relay Unit (also applicable to category 4)