F3SP-U4P-TGR
User's manual
17
7 OPERATING
PROCEDURES.
7.1 DIP-SWITCHES CONFIGURATION.
The configuration indicated in the table must be selected on both the
dip
-
switches
available in the front cover.
4
Function
X not
used
3
Function
Off
muting A-B act on the light curtain 1.
muting C-D act on the light curtain 2.
On
Forbidden
2
Function
1
function
Off
muting 60 s
Off
interlock mode
On
muting
∞
s *
On
automatic
mode
•
The control-unit is Factory default set with the following configuration:
Automatic reset, the maximum duration of the muting: sixty seconds.
* Infinite muting duration: this feature must be used carefully because it’s against
the norm. Using this, the user must know that it’s works under it’s sole
responsibility.
1
2
3
4
ON
4
3
2
1
ON
SW 2
SW 1