![background image](http://html1.mh-extra.com/html/omron/f3sp-u3p-tgr/f3sp-u3p-tgr_user-manual_742107026.webp)
F3SP-U3P-TGR
User's manual
25
12 TECHNICAL DATA.
•
Voltage: 24 Vdc
±
10%
•
Electrical input: 420 mA max.
•
Combinable
photocells:
OMRON E3FS series and
Techno GR S5 – S10 – S30 series
•
Number of photocells: two pairs max
•
Wire range: size AWG 16 – 24 Solid/Stranded
•
Wire type: 60/75 °C copper (Cu) conductor only
•
Torque on terminals: 0.9 N*m
•
Indicators: 5 green LEDs, 1 red LED
•
Response time:
≤
30 ms
•
Working temperature: -10 a + 55 °C
•
Moisture: from 15% to 95% (not condensing)
•
Output contacts: 2 NO, 115 Vac 2.5 A max
•
Switch capability: 1,500 VA, 180W
•
Electrical life expectance: 100.000 op. minimun at 1,800 oprs/hr.
•
Operative distance: according to the type of photocell
E3FS 10m
S5-5
8m
S5-10 8m
S30-5 50m
•
Outer
controls:
start
control,
test
,
muting
and
override
•
Housing: plastic case for installation on a din/omega guide
•
Protection class of control unit: IP 20
•
Protection class of photocells: IP 67
•
Protection class of the cabinet containing the control-unit: IP54 at least
•
Weight: control unit: 300 g
•
Features of fuses
muting
signalling lamp: internal re-settable fuse
315mA 60V
•
Muting
signalling: F39-A11
Summary of Contents for F3SP-U3P-TGR
Page 3: ......
Page 13: ...F3SP U3P TGR User s manual 12 5 2 PIN OVERVIEW ...
Page 27: ...F3SP U3P TGR User s manual 26 13 OVERALL DIMENSIONS Control unit F3SP U3P TGR ...