F3SP-U3P-TGR
User's manual
11
5 CONNECTIONS.
5-1
REFERENCES ON THE TERMINAL BOARD.
TERMINAL BLOCK ASSIGNMENT
TERMIN
AL
OUTER CONNECTION
1 - 2
Connect to the 24 Vdc power supply, 1 to 24Vcc and 2 to
0Vcc
3
Connect the muting signaller LMS.
4
Connect to the ground of plant.
5
TEST button; connect a normally closed button (N.C.).
6
RESET button; connect a normally open button (N.O.).
7
Input of the muting A sensor. Connect to the N.O. contact of
the muting sensor (photocell, proximity switch, other).
8
Input of the muting B sensor. Connect to the N.O. contact of
the muting sensor (photocell, proximity switch, other).
9
Connect the photocells test input of transmitters TX1.
Black wire (pin 4 of connector).
10
Connect to the PNP output of the receivers RX1.
Black wire (pin 4 of connector).
11
Connect the photocells test input of transmitters TX2.
Black wire (pin 4 of connector).
12
Connect to the PNP output of the receivers RX2.
Black wire (pin 4 of connector).
13 - 14
(OUT1) safety output 1 with N.O. contact.
15 - 16
(OUT2) safety output 2 with N.O. contact.