6
Chapter
1
Ra
tings
/Sp
ecif
ic
a
tion
s
F3SJ-B
User’s Manual
Overview and Specifications
Ratings/Specifications
The model names of the F3SJ-B contain the 4 digits indicating the protective height (mm).
*
1. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the safety
output at 4 Hz or less, the usable load inductance becomes larger.
*
2. These values must be taken into consideration when connecting elements including a capacitive load such as a capacitor.
*
3. The Vs indicates a voltage value in your environment.
Item
Model
F3SJ-B
N25-01T
Detection capability
Opaque objects
25 mm diameter
Beam gap
20 mm
Number of beams
8 to 102
Protective height
185 to 2,065 mm
Lens diameter
5 mm
Operating range
0.2 to 7 m
Response time
ON to OFF: 15 ms max. (Response time when used alone or in 2 or 3 connected)
OFF to ON: 70 ms max. (Response time when used alone or in 2 or 3 connected)
Startup waiting time
2 s max.
Power supply voltage (Vs)
SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Current consumption
Refer to "Model/Current Consumption List" on page 8.
Light source
Infrared LED (870 nm wavelength)
Effective aperture angle (EAA)
Based on IEC 61496-2.
Within ±2.5° for both emitter and receiver at an operating range of 3 meters or more.
Safety output (OSSD)
Two NPN transistor outputs, Load current: 200 mA max., Residual voltage: 2 V max.
(except for voltage drop due to cable extension), Leakage current: 1 mA max., Load
inductance: 2.2 H max.
*
1
Maximum capacitive load: 1 µF
*
2
Auxiliary output
One NPN transistor output
Load current: 100 mA max.
Residual voltage: 2 V max.(except for voltage drop due to cable extension)
Leakage current: 1 mA max.
Output operation mode
Safety output: On when receiving light
Auxiliary output: Reverse output of safety output
Input voltage
Test input:
ON voltage: 1/2 Vs to Vs, or open *3 (short circuit current: approx. 3.0 mA)
OFF voltage: 0 V to 3 V (short circuit current: approx. 4.0 mA)
Reset input:
ON voltage: 0 V to 3 V (short circuit current: approx. 4.0 mA)
OFF voltage: 1/2 V to Vs, or open *3 (short circuit current: approx. 3.0 mA)
Overvoltage category
II (IEC 60664-1)
Indicator
Refer to "Internal (LED) Indicator Display Pattern" on page 4.
Mutual interference prevention function
Mutual interference prevention algorithm prevents interference in up to three sets.
Series connection function
Number of connections: Up to three sets
Total number of beams: Up to 192
Maximum connection cable length: 7 m (connection cable (F39-JBR2W) and F3SJ's
cable are not included)
Test function
Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
Summary of Contents for F3SJ-B Series
Page 1: ...F3SJ B N25 01T Series Safety Light Curtain User s Manual Cat No SCHG 735E...
Page 12: ...x Introduction F3SJ B User s Manual...
Page 30: ...16 Chapter 2 Description of Functions F3SJ B User s Manual System Configuration and Functions...
Page 84: ...70 Chapter 3 Wiring F3SJ B User s Manual Wiring Installation...
Page 90: ...76 Chapter 4 Wiring Examples F3SJ B User s Manual Input Output Circuit and Applications...
Page 96: ...82 Chapter 5 Maintenance Checklists F3SJ B User s Manual Checklists...