12
Chapter
2
Des
c
ript
io
n o
f Fun
ction
s
F3SJ-B
User’s Manual
System Configuration and Functions
Description of Functions
External Test Function
This function stops the emission using an external signal. It can be used to verify that a safety system
should properly stop (safety output turns OFF) when F3SJ-B is interrupted.
To stop the emission, set open or apply voltage of 1/2 Vs to Vs to the test input line of the emitter.
Test input
Safety output
ON
OFF
ON
OFF
60 ms max.
140 ms max.