F3S-B
5
Notice
For your safety, always pay attention to the following:
#
Installation Environment
•
Do not install the F3S-B in the following environments:
−
Areas exposed to intense interference light such as direct sunlight.
−
Areas with high-humidity where condensation is likely to occur.
−
Areas exposed to corrosive gases.
−
Areas exposed to vibration or shock levels higher than specification provisions.
−
Areas where the light curtain may come in direct contact with water.
•
Do not use radio equipment, such as cellular phones, walkie-talkies, or transceivers with high power,
near the F3S-B.
#
Wiring and Mounting
•
Be sure to route the F3S-B cable separate from high-potential power lines or through an exclusive
conduit.
•
Be sure to turn OFF the power prior to wiring. Otherwise, the diagnostic function may prevent the
sensor from operating.
•
When using cables with a connector other than the F39-JB series cable, make sure the connector is
rated IP54 or higher.
•
The F3S-B will start operating in two seconds after the power is turned ON. Make sure that no op-
eration faults will occur in the control system during this time.
•
The emitter and receiver are to be mounted in parallel and facing one another.
#
Loads must satisfy all the conditions below.
•
Is not short-circuited.
•
Is not used with current higher than the rating.
•
Is reinforced insulated or double insulated as shown in the following figure to prevent the output
from being subjected to a hazardous voltage when the load is a relay. The insulation shown in the
figure below should insulate against hazardous voltage levels (230 VAC, etc.), not simply against 24
VDC.
Emitter
Receiver
Relay monitoring input
0 V
+24 V
Output
0 V
+24 V
Power
supply unit
Reinforced
insulation or
double
insulation
k1
Reinforced insulation or double
insulation between the coil and
contacts, between contacts
K1
Motor, etc.
Hazardous
voltage level
k1
Hazardous
voltage level
#
Two control outputs must be used.
#
The procedures of installation and inspection in this manual should be read carefully.
#
Do not use any solvents such as paint thinners, benzene or acetone to clean the F3S-B because they
will dissolve resin and paint.
#
Do not use screw-locking adhesives (screw lock) to secure the cap unit or connector cap screws be-
cause the adhesive may cause the resin to deteriorate and crack.
#
The F3S-B can not detect transparent or semi-transparent materials.
#
After unpacking the emitter and receiver, install them facing each other.
#