F3S-B
29
2-3-3 Wiring Procedure
1. Connect the emitter extension cable (F39-JB A-L optional,
gray color outer jacket
) to the emitter.
(The emitter uses gray color plastic caps.)
2. Connect the receiver extension cable (F39-JB A-D optional,
black color outer jacket
) to the receiver.
(The receiver unit uses black color plastic caps.)
3. Connect the 0 V line of the power supply directly to protective earth (PE).
Note:
Be sure to wire correctly. Failure to do so may damage the F3S-B.
•
Connector (Main Unit End)
Signal Name
Front View
Pin No.
Receiver
Emitter
Wire Color
of Extension
Cable
1
Control output 2
Relay monitoring input
White
2
24 VDC
24 VDC
Brown
3
Control output 1
External test input
Green
4
Instability output
Interlock selection input
Yellow
5
RS-485 (A)
RS-485 (A)
Grey
6
RS-485 (B)
RS-485 (B)
Pink
7
0 V
0 V
Blue
1
7
2
8
6
5
3
4
8
N.C. / reserved
N.C. / reserved
Red
N.C. / reserved: do not connect
•
Extension Cable (F39-JB A Optional)
ø1
5
42
L
M12
Round vinyl-insulated cord
5.7 mm dia. (32/0.1 mm dia.) 8 cores
Unit: mm
Type (Set name)
for Emitter
for Receiver
L
F39-JB1A F39-JB1A-L
F39-JB1A-D
3000
F39-JB2A F39-JB2A-L
F39-JB2A-D
7000
F39-JB3A F39-JB3A-L
Gray outer
jacket color
F39-JB3A-D
Black outer
jacket color
10000
•
Series Connection Cable (F39-JB1B Optional)
M12
48.5
300
Unit: mm
Ø
15
Type (Set name)
for Emitter
for Receiver
F39-JB1B F39-JB1B-L
Gray
outer
jacket color
F39-JB1B-D Black
outer
jacket color