F3S-B
13
Type
Item
F3S-B
P
(*1)
Stand-alone
F3S-BM
P
(*1)
Master unit for series
connection
F3S-BS
(*1)
Slave unit for series
connection
Degree of
protection
IEC60529 IP65
Vibration
resistance
Normal operation : 10 to 55 Hz, double-amplitude: 0.7mm, X, Y and Z directions
20 sweeps
Shock resistance
Normal operation : 100 m/s
2
[10 G], X, Y and Z directions: 1000 times
Materials
Case: Aluminum
Front cover: PMMA (acrylic resin)
End caps: PA6
Size
(cross section)
30 x 40 mm
Accessories
Test rod (*3), mounting brackets (top and bottom), mounting brackets (intermedi-
ate) (*4), mounting plates (*4), Instruction manual(*5)
Applicable
standard
IEC(EN)61496-1 TYPE 2 ESPE (Electro-Sensitive Protective Equipment)
IEC 61496-2 TYPE 2 AOPD (Active Opto-electronic Protective Devices)
*1 For detailed type names and optical specifications, see “1-9 Table of Types”.
*2 Nominal value (Set time). The accuracy is – 0 / + 70% of ON to OFF response time.
*3 Only with F3S-B
2P and BM
2P
.
*4 For the 1,050 mm protective height and longer types.
*5 Only with F3S-B
P and BM
P
.
1-8 Indicators
ON
OFF
UNSTAB
POWER
INTER-
LOCK
EXT.TEST/
BLANKING
Optical-axis line mark
ON-state indicator
Instability indicator
OFF-state indicator
IR-power indicator
External test /
Interlock indicator
blanking indicator
<Emitter Indicators>
<Receiver Indicators>
(Orange)
(Yellow)
(Green)
(Orange)
(Red)
(Green)
Emitter
IR-power indicator
Interlock indicator
External test/ blanking indicator
: Lit when emitting.
: Lit during start/restart interlock and start interlock.
: Lit during external test. / Flashing when using blanking
function.
Receiver
ON-state indicator
OFF-state indicator
Instability indicator
: Lit when receiving light.
: Lit with interrupted light.
Flashing during connection with F39-E1 or with failure.
: Lit with an insufficient light reception or failure.
Flashing during connection with F39-E1.