Dimensions

Unit: mm (inch)

TEMPERATURE CONTROLLERS

40

(1.57)

E5ZE-8

AAM

B-E

Mounting Holes

Mounting Stud

Panel-mounting Screws

Prepare the following screws.
Size:

M3 x 

ȏ

t + t

1

 + t

2

 + 2.5 < 

ȏ

 < t + t

1

 + t

2

 + 7.8

t:

Panel thickness

t

1

: Spring washer thickness

t

2

: Flat washer thickness

Material: Iron or stainless

Mounting
bracket

M3 x 6
mounting
screws

The mounting brackets
can be mounted to the
position marked with *.

*

M3 depth: 
8 (0.31)

*

t

2

t

1

Mounting bracket

*

Mounting bracket

*

220

±

0.4

(8.66

±

0.016)

40

±

0.2

(1.57

±

0.008)

65 (2.56)

85.5 (3.37)

60

(2.36)

131.1

(5.16)

220

(8.66)

206

(8.11)

11

(0.43)

173.5 (6.83)

145 (5.71)

M4

DISPLAY UNIT

E5ZD-SDL

Panel Cutouts

L = (96N – 3.5)

+1

 0

11 (0.43)

89 (3.50)

12

(0.47)

96 x 96 (3.78 x 3.78)

Mounting
 screw

L

120

(4.72)

min.

+0.8
 0

Side-by-side Mounting
of N Controllers

92

(3.62)

+0.8
 0

92

(3.62)

+0.8
 0

92

(3.62)

Summary of Contents for E5ZE-8 E Series

Page 1: ...nts Control method Part number controlled Thermocouple input Platinum resistance thermometer input 8 Heating standard See Note E5ZE 8AAAMTCB E E5ZE 8AAAMPB E Heating cooling E5ZE 8VAAMTCB E E5ZE 8VAAMPB E Note The output operation can be switched to provide cooling control INPUT AND OUTPUT BOARDS Description Specifications Max quantity Part number Control output board Voltage output 8 points 30 mA...

Page 2: ...ng without software 1 4 DIN size RS 422 terminal block 100 to 240 VAC 50 60 Hz supply voltage E5ZD SDL2X AC100 240 software 1 4 DIN size RS 422 terminal block 24 VDC supply voltage E5ZD SDL2X 24V DC RS 485 terminal block 100 to 240 VAC 50 60 Hz supply voltage E5ZD SDL3X AC100 240 RS 485 terminal block 24 VDC supply voltage E5ZD SDL3X 24V DC 1 5 m length cable from E5ZE to Display Unit RS 232C with...

Page 3: ...Max voltage 30 VDC Max load current 50 mA output Residual voltage when ON 2 VDC max Leakage current when OFF 1 mA max Alarm outputs Temperature alarms Two outputs alarm 1 and alarm 2 for all outputs in each word HB alarm heater burnout detection One output for all outputs in each word HS alarm SSR fault detection One output for all outputs in each word Temperature controller error output memory se...

Page 4: ...tance Malfunction 10 to 55 Hz with 15 m s2 1G for 10 minutes each in X Y and Z directions Destruction 10 to 55 Hz with 20 m s2 2G for 2 hours each in X Y and Z directions Shock resistance Malfunction 150 m s2 15 3G max 3 times each in X Y and Z directions Destruction 200 m s2 20 4G max 3 times each in X Y and Z directions Enclosure rating IP00 Weight Enclosed Unit 1 700 g max Open frame 900 g max ...

Page 5: ...S 422 RS 485 Maximum total cable length 15 m 500 m 500 m Communications method Half duplex Connection method 25 pin D sub connector 5 pole terminal block with M3 screws Transmission line configuration 3 wire 4 wire 2 wire Transmission line type Direct line Multi drop line Synchronization method Start stop synchronization asynchronous Baud rate 2 400 4 800 9 600 19 200 bps Transmission code ASCII N...

Page 6: ...lled 8 Auto tuning AT indicator Flashes while auto tuning is being executed 9 Heater burnout Heater short circuit HB HS alarm indicator Lit when heater burnout or heater short circuit alarm output is ON 10 Alarm 1 indicator Lit when alarm output 1 is ON 11 Alarm 2 indicator Lit when alarm output 2 is ON Key No Key Meaning 12 Shift Key Turns ON or OFF the shift indicator 13 Unit Point Key Displays ...

Page 7: ...put Memory bank designated input Alarm output Cooling side control output heating and cooling control models only G7TC OC16 Relay Output Block or P7TF OS16 Relay Base with 16 G3TA ODX02S SSRs installed G7TC OC08 E5ZE CBL E5ZE CBL E5ZE CBL CT INPUT CONTROL Computer E5ZE ALARM Connections Use E5ZE CBL Connecting Cables to connect the following devices to the E5ZE Screw Terminals XW2B 20G4 and XW2B 2...

Page 8: ...r stainless Mounting bracket M3 x 6 mounting screws The mounting brackets can be mounted to the position marked with M3 depth 8 0 31 t2 t1 Mounting bracket Mounting bracket 220 0 4 8 66 0 016 40 0 2 1 57 0 008 65 2 56 85 5 3 37 60 2 36 131 1 5 16 220 8 66 206 8 11 11 0 43 173 5 6 83 145 5 71 M4 DISPLAY UNIT E5ZD SDL Panel Cutouts L 96N 3 5 1 0 11 0 43 89 3 50 12 0 47 96 x 96 3 78 x 3 78 Mounting s...

Page 9: ... of the above thermocouples is a point number Platinum Resistance Thermometer Platinum resistance thermometer 0 Platinum resistance thermometer 1 Platinum resistance thermometer 2 Platinum resistance thermometer 3 Platinum resistance thermometer 4 Platinum resistance thermometer 5 Platinum resistance thermometer 6 Platinum resistance thermometer 7 DC DON T USE DC DON T USE FG Make sure there in no...

Page 10: ...for G7TC 12 or 24 VDC G7TC OC08 Relay I O Block G7TC OC16 Alarm Output and Cooling Side Control Output For Heating and Cooling Control Models Only Point number G7TC OC16 Relay I O Block Drive power supply for G7TC 12 or 24 VDC Not used Temperature Controller error HS alarm Alarm output Alarm 1 HB alarm Alarm 2 Not used Cooling side control output Do not use these terminals when using an E5ZE heate...

Page 11: ... system Transmission length 500 m max in total RS 485 Terminal Signal name Symbol Signal direction 1 Not used 2 Not used 3 Signal ground SG 4 Terminal B B I O 5 Terminal A A I O Electrical characteristics Conforming to EIA RS 485 Synchronization clock Internal Maximum E5ZE Units connectable 16 excluding host system Transmission length 500 m max in total Communications Switch Settings Setting RS 42...

Page 12: ... RS 232C 13 1 25 14 RS 232C Pin Connection E5ZD SDL2 X Electrical Characteristics Conforming to EIA RS 422 Connecting Signals Signal name Symbol Signal direction Terminal block pin number Send data A SDA Output 21 Send data B SDB Output 20 Receive data A RDA Input 23 Receive data B RDB Input 24 Signal ground SG 22 Field ground FG E5ZD SDL3 X Electrical Characteristics Conforming to EIA RS 485 Conn...

Page 13: ...2C E53 E04 for RS 422 RS 485 E54 E8CT E53 E8Q for voltage output E53 E8C for current output or Use this CT input unit in combination with the E53 E8Q voltage output unit or Tighten the screws through the holes marked with a black dot to the mounting studs of the E5ZE Mounting Position of I O Units Communication Unit CT Input Unit Output Unit Connector Communication Unit CT Input Unit Connector Out...

Page 14: ...ds 5 Attach the Units in the designated position Connect the Units and the E5ZE connector properly 6 Attach the Units to the studs with mounting screws with a torque of 0 43 to 0 58 N m 7 Attach the connector to the case using the connector mounting screws with a torque of 0 34 to 0 39 N m 8 Replace the casing in its original position using six casing mounting screws Casing securing Case Casing Re...

Page 15: ...block and connectors must not face up otherwise operating errors may result Prepare four M4 screws to mount the E5ZE to control panels Use flat washers and spring washers with screws to mount the E5ZE to control panels so that the screws will not loosen The mounting brackets must be attached to the E5ZE with the four M3 x 6 screws provided with the E5ZE and each of the screws should be tightened t...

Page 16: ... unit 24 VDC E5ZE FG Outside the control panel Inside the control panel I O terminals Communications cable Power supply PLC or Alarm output Control output CT input E5ZE CBL 00 Platinum resistance thermometer input Thermocouple input Note 1 Place the power supply filter input sensor I O terminals and communications cable inside the control panel when wiring them 2 If the communications cable betwee...

Page 17: ...C13 8 00 Specifications subject to change without notice Printed in U S A OMRON ELECTRONICS INC One East Commerce Drive Schaumburg IL 60173 1 800 55 OMRON OMRON CANADA INC 885 Milner Avenue Scarborough Ontario M1B 5V8 416 286 6465 R ...

Reviews: