Specifications
Conformity to Safety Standards
100 V to 240 V AC (50/60 Hz), 24 V AC/DC (50/60 Hz)
100 V to 120 V AC (50/60 Hz), 24 V AC/DC (50/60 Hz)
85% to 110% of rated voltage
E5AR: 22 VA max. (100 V to 240 V AC), 15 VA / 10 W max. (24 V AC/DC)
E5ER: 17 VA max. (100 V to 240 V AC), 11 VA / 7 W max. (24 V AC/DC)
Thermocouple input: (larger of
±
0.1% PV or
±
1˚C)
±
1 digit max.
However, there are some exceptions.
Analog input: (
±
0.1% FS)
±
1 digit max.
Platinum resistance temperature input: (larger of
±
0.1% PV or
±
0.5˚C)
±
1 digit max.
Position proportional potentiometer input: (
±
5% FS)
±
1 digit max.
Voltage output: 12 V DC, 40 mA max. * 1, with short-circuit protection circuit
*1:The value for the E5AR-TQQ
□□□
WW-
□□□
is 21 mA max.
Current output: 0 to 20 mA DC, 4 to 20 mA DC; load of 500
Ω
max.
Resolution: Approx. 54,000 at 0 to 20 mA DC
Approx. 43,000 at 4 to 20 mA DC
Position proportional control type Relay output: open, closed
1a 250 V AC, 1A (including inrush current)
Electrical life: 100,000 operations
±
0.3%FS
Resolution: Approx. 54,000 at 0 to 20 mA DC, Approx. 43,000 at 4 to 20 mA DC
Relay output 1a 250 V AC 1 A (resistive load)
Electrical life: 100,000 operations
Transistor output: Maximum load voltage: 30 V DC, maximum load current: 50 mA,
leakage current: 0.4 mA or less, residual voltage: 1.5 V or less
Advanced PID or ON/OFF
-10 to +55˚C (no condensation or icing)
25 to 85%
-25 to +65˚C (no condensation or icing)
2000 m max.
100 to 240 V AC type: 50 A max.; 24 V AC/DC type: 30 A max.
T4A, 250 V, time lag, low insulation capacity
E5AR: approx. 450 g (Main Unit only), fittings: approx. 60 g, terminal cover: approx. 30 g
E5ER: approx. 330 g (Main Unit only), fittings: approx. 60 g, terminal cover: approx. 16 g
Overvoltage category ll, pollution degree 2 (according to UL61010-1,
CSA C22.2 No. 61010-1, EN/IEC61010-1)
Short-circuit current: Approx. 4 mA
Contact input ON: 1 k
Ω
max., OFF: 100 k
Ω
min.
Non-contact input ON: residual voltage of 1.5 V max., OFF: leakage current of 0.1 mA max.
Non-volatile memory (Number of rewrites: 100,000 times)
As shown in the diagram, each functional block
of the E5AR/ER is electrically insulated. <inputs>,
<event inputs/voltage outputs/current outputs>,
and <communication> are functional insulation
each other.
<inputs/ event inputs/ voltage outputs/ current
outputs/ communication> <relay output/
transistor output> are reinforced insulation each
other.
Power
supply
Relay Output
Transistor Output
Input 1 / Potentiometer Input
Input 2
Input 3
Input 4
Communication
Event Input, Voltage Output,
Current Output
: (1)100 to 120 VAC
24 VAC/DC
Reinforced insulation
(2)120 to 240 VAC
Basic insulation
: Basic
insulation
: Functional
insulation
Power supply voltage (CE marking)
Power supply voltage
(UL certification)
Permissible voltage range
Power consumption
Indication accuracy
Control output
Transfer output
Auxiliary output
Control method
Ambient operating temperature
Ambient operating humidity
Storage temperature
Altitude
Inrush current
Recommended fuse
Weight
Installation environment
Event input
Memory protection
Long-term: 250V+ (Supply voltage)
Short-term: 1200V+ (Supply voltage)
100 to 240 V AC
Temporary overvoltage
4