47
7-1-3 Signal Input Method
The event input terminals can be short-circuited using a relay or transistor as
shown in the following diagram.
+24 V
0 V
470
Ω
VF = 1.2
VF = 0.6
COM
Internal circuitry
EV*
3 k
Ω
Flow current:
7 mA approx.
Signal Input Types
EV*
COM
ON: A resistance of 1 k
Ω
max.
OFF: A resistance of 100 k
Ω
min.
EV*
COM
ON: A residual voltage of 3 V max.
OFF: A current leakage of 1 mA max.
Contact Input
No-contact Input
(Open collector)
The following table lists the event input terminal numbers for each model.
Model
E5AJ/E5EJ
E5CJ
Input terminal
EV1
20
14
EV2
19
---
COM
17
13
Event Input Function
Section 7-1