
E5AK/E5CK/E5EK
E5AK/E5CK/E5EK
95
Input Types (selectable with input jumper connector)
Thermocouple
Input (field
selectable)
(See Notes)
K1
K2
J1
J2
T
E
L1
L2
U
N
R
S
B
W
PLII
Range
°
C
–200
to
1,300
0.0
to
500.0
–100
to
850
0.0
to
400.0
–199.9
to
400.0
0
to
600
–100
to
850
0.0
to
400.0
–199.9
to
400.0
–200
to
1,300
0
to
1,700
0
to
1,700
100
to
1,800
0
to
2,300
0
to
1,300
°
F
–300
to
2,300
0.0
to
900.0
–100
to
1,500
0.0
to
750.0
–199.9
to
700.0
0
to
1,100
–100
to
1,500
0.0
to
750.0
–199.9
to
700.0
–300
to
2,300
0
to
3,000
0
to
3,000
300
to
3,200
0
to
4,100
0
to
2,300
Note: 1. Setting number is factory-set to 2 (K1).
2. Thermocouple W is W/Re5-26 (tungsten rhenium 5, tungsten rhenium 26).
Platinum Resistance Thermometer (RTD’s)
Input (field selectable)
JPt100
Pt100
Range
°
C
–199.9 to 650.0
–199.9 to 650.0
°
F
–199.9 to 999.9
–199.9 to 999.9
Current/Voltage
Input (field selectable)
Current input
Voltage input
4 to 20 mA
0 to 20 mA
1 to 5 V
0 to 5 V
0 to 10 V
Note: When a current/voltage input is selected, the decimal point is fully adjustable.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com