E5AK/E5CK/E5EK
E5AK/E5CK/E5EK
124
CONTROL OUTPUT
E5AK Control Output
Terminal numbers 7 and 8 are for control output 1 (OUT1), and terminal numbers 5 and 6 are for control output 2 (OUT2). The following
diagrams show the available Output Modules and their internal circuits.
E5EK Control Output
Terminal numbers 7 and 8 are for control output 1 (OUT1), and terminal numbers 5 and 6 are for control output 2 (OUT2). The following
diagrams show the available Output Modules and their internal circuits.
With E53-V
Output Modules, approx. 2 V is output for one second after the power is interrupted.
E5AK-PRR2/E5EK-PRR2 Controllers
The E5AK-PRR2 and E5EK-PRR2 Controllers are supplied with relay output. This relay output is not compatible with any other module.
When replacing the Output Module, use the E53-R. The following diagrams show the relationship between terminals and open/close relay
settings.
8
7
Open
6
5
Close