background image

E3C-LDA

@

N

12

Amplifier Units

This product is not designed or rated for ensuring 
safety of persons either directly or indirectly.
Do not use it for such purposes.

Do not use the product with voltage in excess of the 
rated voltage.
Excess voltage may result in malfunction or fire.

Never use the product with an AC power supply.
Otherwise, explosion may result.

The following precautions must be observed to ensure safe operation 
of the Amplifier Unit. Doing so may cause damage or fire.

1.

Do not install the product in the following locations.

• Locations subject to direct sunlight
• Locations subject to condensation due to high humidity
• Locations subject to corrosive gas
• Locations subject to vibration or mechanical shocks exceeding 

the rated values

• Locations subject to exposure to water, oil, chemicals
• Locations subject to stream
• Locations subjected to strong magnetic field or electric field

2.

Do not use the product in environments subject to flammable or 

explosive gases.

3.

Do not use the product in any atmosphere or environment that 

exceeds the ratings.

4.

To secure the safety of operation and maintenance, do not install 

the product close to high-voltage devices and power devices.

5.

High-voltage lines and power lines must be wired separately from 

the product. Wiring them together or placing them in the same duct 

may cause induction, resulting in malfunction or damage.

6.

Do not apply any load exceeding the ratings. Otherwise, damage 

or fire may result.

7.

Do not short the load. Otherwise, damage or fire may result.

8.

Connect the load correctly.

9.

To use this device as connecting with each other, be sure to 

connect with the same power supply and turn ON the power 

simultaneously. Using a separate power supply will influence the 

functions when connecting the devices to use them.

10.

Do not use the product if the case is damaged.

11.

Burn injury may occur. The product surface temperature rises 

depending on application conditions, such as the ambient 

temperature and the power supply voltage. Attention must be paid 

during operation or cleaning.

12.

When setting the sensor, be sure to check safety such as by 

stopping the equipment.

13.

Be sure to turn off the power supply before connecting or 

disconnecting wires.

14.

Do not attempt to disassemble, repair, or modify the product in any 

way.

15.

When disposing of the product, treat it as industrial waste.

16.

Do not use the Sensor in water, rainfall, or outdoors.

17.

If you notice any abnormal condition, immediately stop using the 

product, turn off the power and consult your dealer without doing 

any operation such as initialization.

18.

Sensor heads other than those for E3C-LDA

@@

N cannot be used. 

It may be damaged if connected.

1.

Do not miswire such as the polarity of the power supply.

2.

Be sure to mount the unit to the DIN track until it clicks.

3.

When using a connector type product, place a protective label 

(provided with the E3X-CN series) on the power supply connecting 

terminals that are not used, to prevent electric shock or short 

circuit.

4.

The length for the cable extension must be 30 m or less. Be sure 
to use a cable of at least 0.3 mm

2

 for extension.

5.

Do not apply the forces on the cord exceeding the following limits: 

Pull: 40 N; torque: 0.1 N·m; pressure: 20 N; bending: 29.4 N

6.

Do not apply excessive force such as tension, compression or 

torsion to the connector of the sensor head that is fixed to the 

amplifier unit.

7.

Always keep the protective cover in place when using the product. 

Not doing so may cause malfunction.

8.

It may take time until the received light intensity and measured 

value become stable immediately after the power is turned on 

depending on use environment.

9.

The product is ready to operate 300 ms after the power supply is 

turned ON.

10.

The Mobile Console E3X-MC11, E3X-MC11-SV2 and 

E3X-MC11-S cannot be connected.

11.

The mutual interference prevention function works when between 

E3C-LDAN. The mutual interference will occur if other amplifier 

units are used.

12.

Sensor heads other than those for E3C-LDAN cannot be used. It 

may be damaged if connected.

13.

If the unit receives excessive sensor light, the mutual interference 

prevention function may not work properly, resulting in malfunction 

of the unit. In such case, increase the threshold.

14.

The Communication Unit E3X-DRT21-S, E3X-CRT, E3X-ECT and 

E3NW cannot be connected.

15.

Do not use thinner, benzine, acetone, and lamp oil for cleaning.

16.

The amplifier unit uses EEPROM memory to save the 

configuration information. If the memory rewritable time exceeds 

its limit (100,000 times), the memory error will be displayed and 

the amplifier unit needs to be replaced. Memory data is rewritten, 

for each operation, three times when tuning, processing zero 

reset, and changing the hysteresis width, and ten times when 

initializing the settings.

17.

If a crossed out wheelie bin symbol is labeled on the 

amplifier unit, dispose in accordance with applicable 
regulations.

 WARNING

Precautions for Safe Use

Precautions for Correct Use

Protective Label

Power Supply Connecting Terminal

Summary of Contents for E3C-LDA-N Series

Page 1: ...ight from the workpiece Coaxial Optical System Sensing distance of 7 m Sensing distance of 1 m At 1 m Minimum spot diameter of 0 8 mm Optical axis alignment range Approximately r1 to1 5q Spot Line and...

Page 2: ...e for details Use a standard model E39 R12 R13 if the distance from the Sensor is 400 mm or more Use the short distance model E39 R14 if the distance is less than 400 mm Sensing method Appearance Beam...

Page 3: ...mm 2 m 700 mm 400 mm 2 m Standard Mode Stnd 30 to 700 mm 5 m 1 300 mm 700 mm 5 m Giga Mode GIGA 30 to 1000 mm 7 m 1 700 mm 900 mm 7 m Focus 3 0 8 mm max at distances up to 300 mm 33 mm at 150 mm 33 1...

Page 4: ...evention 3 Super High speed Mode SHS 0 Note The mutual interference prevention function is disabled when the detection mode is set to High Speed mode SHS High speed Mode HS 10 Standard Mode Stnd 10 Gi...

Page 5: ...on 220 200 180 160 140 120 100 80 60 40 20 0 FOCUS control turned all the way to right FOCUS control turned to center FOCUS control turned all the way to left 100 300 200 500 400 600 900 700 800 1000...

Page 6: ...ncident light Lit Not lit ON OFF Operate Reset OUT indicator orange Output transistor Load e g relay Between brown and black leads lit L Load OUT indicator orange Display Photoelectric sensor main cir...

Page 7: ...ight Lit Not lit ON OFF Operate Reset OUT indicator orange Output transistor Load e g relay Between blue and black leads lit L 12 to 24 VDC Load Brown Black Orange Blue OUT indicator orange Display Ph...

Page 8: ...ning is in progress Performs tuning and ST Indicator turns ON Threshold Level Green digital display Incident Level White digital display UP DOWN Button Used to fine tune the threshold MODE Button Swit...

Page 9: ...rew with 60 mN m or less to avoid a risk of damage or fire 9 When disposing of the product treat as industrial waste 10 If you notice an abnormal condition such as a strange odor extreme heating of th...

Page 10: ...nges when the angle is adjusted adjust the focus again Shortening the Connection Cable 1 Removing the Connector Using a flat blade screwdriver press the lever in the opening next to the cable and then...

Page 11: ...ified as a class II laser by the FDA and it has already been registered with the CDRH Center for Devices and Radiological Health Ask your OMRON representative for details Laser Labels Technical standa...

Page 12: ...outdoors 17 If you notice any abnormal condition immediately stop using the product turn off the power and consult your dealer without doing any operation such as initialization 18 Sensor heads other...

Page 13: ...e catch the track 2 Push the unit until the hook clicks into place Removing from DIN Track 1 Push the unit in the direction 1 2 Lift the unit in the direction of arrow 2 while performing step 1 Do not...

Page 14: ...8 8 4 3 7 4 75 Emitter 6 Receiver 27 3 1 18 8 20 5 1 27 7 33 33 R4 8 Two 3 2 dia holes Two R2 6 6 5 18 8 0 1 25 25 Two M3 5 1 0 1 Mounting Holes Two R2 6 1 4 1 LD ON indicator Operation indicator Opti...

Page 15: ...2 13 2 4 4 Mounting Holes 18 8 0 1 Two R2 6 6 9 2 1 3 6 1 3 1 34 18 8 21 9 25 25 6 LD ON indicator Operation indicator Optical axis alignment screw FOCUS Adjustment Screw E3C LR11N only 6 6 12 1 3 di...

Page 16: ...f conductor 0 2 mm2 Insulator dia 0 9 mm Standard length 2 m Side B 12 7 114 114 max value with Protective cover open 19 2 170 max value with Protective cover open 16 3 4 4 4 5 3 9 41 5 167 8 167 8 ma...

Page 17: ...ver open 16 3 4 4 4 5 3 9 41 5 167 8 167 8 max value with Protective cover open Two M3 16 Mounting Holes 30 2 32 1 37 33 5 33 5 3 4 4 2 5 2 6 9 3 4 0 25 4 9 2 6 36 7 57 7 83 4 83 4 27 8 30 9 27 1 32 1...

Page 18: ...h 4 conductors Standard cable length 2 m Conductor cross section 0 2 mm2 AWG24 Insulator diameter 1 1 mm 0 Master Connector E3X CN21 7 Cable Cable 4 dia cable with 2 conductors Standard cable length 2...

Page 19: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Page 20: ...7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Kyoto JAPAN OMRON ASIA PA...

Reviews: