Engineering Data (Typical Examples)

Influence of Temperature on Detection Level

Precautions

To ensure safety, be sure to observe the following precautions.

Wiring

Power Supply Voltage

• Do not use voltages above the allowable range. Applying a

voltage above the allowable range or applying an AC volt-
age (100 VAC) to a DC-type Sensor may result in burning
or damage.

Load Short-circuits

• Do not short-circuit the load. Doing so may result in burn-

ing or damage.

Incorrect Wiring

• Be sure to perform wiring correctly. Incorrect wiring may

result in burning or damage.

No-load Connection

• Connecting the power supply directly to the Sensor without

a load may result in burning or damage to internal ele-
ments. Be sure to connect a load when wiring.

Installation

Influence of Surrounding Objects

• Performance may be adversely affected by conductive

objects (e.g., metals) in the vicinity of the Sensor. Ensure
that any conductive objects are separated from the Sensor
by at least the distances shown below.

Influence of Surrounding Objects

(Units: mm)

Mutual Interference

• When installing 2 or more Sensors in series, in parallel, or

facing each other, be sure that they are separated by at
least the distances shown below.

Mutual Interference

(Units: mm)

*

The detection level for the top Sensor may change when the
detection level for the bottom Sensor is set. Be sure to set the
detection level for the bottom Sensor first.

General Precautions

6

4

2

0

-2

-4

-6

Pipe diameter: 11 mm; Liquid: Distilled water
Pipe diameter: 11 mm; Liquid: Salt water
Pipe diameter: 8 mm; Liquid: Distilled water
Pipe diameter: 8 mm; Liquid: Salt water

-10

0

20

10

30

40

50

60

Temperature (˚C)

Change in detection level (mm)

6

4

2

0

-2

-4

-6

Pipe diameter: 26 mm; Liquid: Distilled water
Pipe diameter: 26 mm; Liquid: Salt water
Pipe diameter: 12 mm; Liquid: Distilled water
Pipe diameter: 12 mm; Liquid: Salt water

-10

10

0

20

30

40

50

60

Temperature (˚C)

Change in detection level (mm)

E2K-L13MC1

E2K-L26MC1

Correct Use

Model

Dimension

A

B

C

E2K-L13MC1

25

5

45

E2K-L26MC1

0

40

A

Sensor

Pipe

B

C

Object on Opposite Side

Object on One Side

Objects on Both Sides

Model

Dimension

*

E

F

E2K-L13MC1

10

10

25

E2K-L26MC1

30

D

E

F

Installed in 

Series Sides

Installed Facing 

Each Other

Installed in 

Parallel

Summary of Contents for E2K-L

Page 1: ...4 7107 Regional Headquarters OMRON EUROPE B V Sensor Business Unit Carl Benz Str 4 D 71154 Nufringen Germany Tel 49 7032 811 0 Fax 49 7032 811 199 OMRON ELECTRONICS LLC 1 East Commerce Drive Schaumburg IL 60173 U S A Tel 1 847 843 7900 Fax 1 847 843 8568 OMRON ASIA PACIFIC PTE LTD 83 Clemenceau Avenue 11 01 UE Square 239920 Singapore Tel 65 835 3011 Fax 65 835 2711 OMRON CHINA CO LTD BEIJING OFFIC...

Page 2: ...ers allowing reductions in stock requirements Binding band Slip prevention tube 12 step sensitivity adjuster Operation indicator 20mm 24mm 33mm Little influence from bubbles Not influenced by the color of the pipe or liquid Use for pipes with diameters in the range 8 to 11 mm or 12 to 26 mm Conforms to CE standards Conforms to CE standards an indispensable requirement for semiconductor manufacturi...

Page 3: ... pipe or liquid Available in 8 to 11 mm dia and 12 to 26 mm dia models to enable sensing for a wide range of pipe diameters Space saved with built in amplifier Sensing method Applicable pipe diameters Appearance Output format Model number Electrostatic capacity method 8 to 11 mm dia NPN open collector output NO E2K L13MC1 12 to 26 mm dia E2K L26MC1 Liquid surface level detection ...

Page 4: ...on of liquid surface Notch position For details refer to Sensitivity Adjustment on page 6 Indicator Operation indicator orange Ambient temperature Operating 0 to 55 C Storage 10 to 65 C with no icing or condensation Ambient humidity Operating storage 25 to 85 with no condensation Temperature influence In the range 0 to 55 C Detection level at 23 C 4 mm with distilled water or 20 concentration salt...

Page 5: ...ence of Surrounding Objects Units mm Mutual Interference When installing 2 or more Sensors in series in parallel or facing each other be sure that they are separated by at least the distances shown below Mutual Interference Units mm The detection level for the top Sensor may change when the detection level for the bottom Sensor is set Be sure to set the detection level for the bottom Sensor first ...

Page 6: ...el to be detected After the Sensor is mounted adjust the detecting sensitivity using the 12 step sensitivity adjuster in the way shown below Note 1 While adjusting the sensitivity do not put your hand on the Sensor and make sure that the cable is properly secured Failure to observe these points may affect the detection level Note 2 When using more than one Sensor e g to detect for upper and lower ...

Page 7: ...s in temperature because this will shorten the service life Miscellaneous Drift may occur when the power supply is turned ON If the dielectric constant of the liquid is low the detection level of the liquid may be 2 to 3 mm higher than the set level for approximately 20 minutes after power is turned ON Dimensions Units mm Correct Use 20 5 43 41 33 R6 5 24 11 5 1 5 6 5 1 3 5 6 6 Sensitivity adjuste...

Reviews: