Cylindrical Inductive Sensor for AC Power Supply
Specifications
Plastic Housing (E2F)
Model
E2F-X1R5Y
@
E2F-X2Y
@
E2F-X5Y
@
E2F-X10Y
@
Sensing distance
1.5 mm ±10%
2 mm ±10%
5 mm ±10%
10 mm ±10%
Setting distance
0 to 1.2 mm
0 to 1.6 mm
0 to 4 mm
0 to 8 mm
Differential distance
10% max
Sensing object
Ferrous metal (Sensitivity lowers with non-ferrous metals)
Standard sensing object
Iron, 8 x 8 x 1 mm
Iron, 12 x 12 x 1 mm
Iron, 18 x 18 x 1 mm
Iron, 30 x 30 x 1 mm
Response frequency
*1
*1. The response frequencies are average values measured on condition that the distance between each sensing object is twice as large as the size of the sensing
object and the sensing distance set is half of the maximum sensing distance.
25 Hz
Power supply
(Operating voltage
range)
24 to 240 VAC (20 to 264 VAC)
Leakage current
1.7 mA at 200 VAC
Control
output
Switching
capacity
5 to 100 mA
5 to 300 mA
Residual
voltage
Refer to the Specifications
Indicator lamp
Operation indicator (red LED)
Operation status
(with sensing object
approaching)
Y1 Models: ON
Y2 Models: NC
Protection circuit
None
*2
*2. Short circuit protection types are available.
Ambient temperature
Operating/Storage: –25 °C to 70 °C (with no icing or condensation)
Ambient humidity
Operating/Storage: 35% to 95% RH
Temperature influence
A maximim fluctuation of ±10% max. of sensing distance at 23 °C in the temperature range of –25 °C to 70 °C
Voltage influence
±1% max. of sensing distance within a range of ±10% of rated power supply voltage
Insulation resistance
50 M
Ω
min. (at 500 VDC) between current carry parts and case
Vibration resistance
10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 1,000 m/s
2
for 10 times each in X, Y, and Z directions
Protective structure
IEC IP68
*3
*3.
OMRON test method
Conditions: Less than 10 m natural state under water
(1) It is not flooded underwater with two atmospheric pressure for 1 hour.
(2) A heat shock cycle (it is 1 hour, respectively to 0 °C cold water and 70 °C warm water) is repeated 20 times, and the performance of detection distance and
insulation resistance is checked.
Connection method
Pre-wired models (standard length 2 m)
Weight (Packed state)
Approx. 40 g
Approx. 50 g
Approx. 130 g
Approx. 170 g
Material
Case
Polyarylate
Sensing
surface
Clamping
nut
Polyarylate resin
Accessories
Instruction manual