![background image](http://html1.mh-extra.com/html/omron/e2e-x10my1/e2e-x10my1_datasheet_740839003.webp)
3
E2E-
@
Y/E2F-
@
Y
Metal Housing (E2E)
Size
M8
M12
M18
M30
Type
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
Item
E2E-X1R5Y
@
E2E-X2MY
@
E2E-X2Y
@
E2E-X5MY
@
E2E-X5Y
@
E2E-X10MY
@
E2E-X10Y
@
E2E-X18MY
@
Sensing distance
1.5 mm ±10% 2 mm ±10%
2 mm ±10%
5 mm ±10%
5 mm ±10%
10 mm ±10% 10 mm ±10% 18 mm ±10%
Set distance
0 to 1.2 mm
0 to 1.6 mm
0 to 1.6 mm
0 to 4.0 mm
0 to 4.0 mm
0 to 8.0 mm
0 to 8.0 mm
0 to 14.0 mm
Differential travel
10% max. of sensing distance
Sensing object
Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to
Engineering Data
.)
Standard sensing
object
Iron, 8 x 8 x
1 mm
Iron,12 x 12
x 1 mm
Iron, 12 x 12
x 1 mm
Iron, 15 x 15
x 1 mm
Iron, 18 x 18
x 1 mm
Iron, 30 x 30
x 1 mm
Iron, 30 x 30
x 1 mm
Iron, 54 x 54
x 1 mm
Response speed
25 Hz
Power supply voltage
(operating voltage
range)
*1
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is over –25 °C.
24 to 240 VAC, 50/60 Hz (20 to 264 VAC)
Leakage current
1.7 mA max.
Control
output
Load
current
*2
*2. When using an M18- or M30-sized E2E within an ambient temperature of 70 °C to 85 °C, make sure that the E2E has a control output of 5 to 200 mA max.
5 to 100 mA
5 to 200 mA
5 to 300 mA
Residual
voltage
Refer to
Engineering Data
.
Indicator
Operation indicator (red LED)
Operation mode
(with sensing object
approaching)
Y1 Models: NO
Y2 Models: NC
For details, refer to
Timing Charts
.
Protection circuit
Surge suppressor
Ambient temperature
*1
*2
Operating/Storage:
–25 °C to 70 °C (with no
icing or condensation)
Operating/Storage: –40 °C to 85 °C (with no icing or condensation)
Ambient humidity
Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
±10% max. of sensing
distance at 23 °C in the
temperature range of
–25 °C to 70 °C
±15% max. of sensing distance at 23 °C in the temperature range of –40 °C to 85 °C
±10% max. of sensing distance at 23 °C in the temperature range of –25 °C to 70 °C
Voltage influence
±1% max. of sensing distance in the rated voltage range ±15%
Insulation resistance
50 M
Ω
min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
4,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case (2,000 VAC for M8 Models)
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
500 m/s
2
10 times each in X,
Y, and Z directions
1,000 m/s
2
10 times each in X, Y, and Z directions
Degree of protection
IEC 60529 IP67 (Pre-wired models: JEM standard IP67g (waterproof, oil-proof))
Connection method
Pre-wired models (standard length 2 m), connector models
Weight
(packed
state)
Pre-wired
models
Approx. 60 g
Approx. 70 g
Approx. 130 g
Approx. 175 g
Connector
models
Approx. 15 g
Approx. 25 g
Approx. 40 g
Approx. 90 g
Material Case
Stainless steel (SUS303)
Brass-nickel plated
Sensing
surface
PBT (polybutylene terephthalate)
Clamping
nuts
Brass-nickel plated
Toothed
washer
Iron-zinc plated
Accessories
Instruction manual