19
Monitoring
Function
Item
Description
All
On/Off
Enables/disables the function.
Startup
Monitoring
timer
Specifies a monitoring time for startup.
If the startup process was not completed within the specified
period, the RAS Board detected a Startup failure.
No
Action
No action when a Startup failure occurs.
Reset
The RAS Board forces the Motherboard to reset on a
Startup failure.
If the next startup process was not completed within the
specified period again, the trial repeats up to a specified
number of times in [Try to restart].
On error...
Power
OFF
The RAS Board forces the Motherboard to Power Off
when a Startup failure occurs.
Try to reset Specifies a number of times to repeat the restart cycle.
Alive
Monitoring
Cycle
Specifies monitoring intervals for the Alive check.
If the RAS service does not respond within the specified period,
the RAS Board detected an Alive Failure.
No
Action
No action when the Alive failure occurs.
Reset
The RAS Board forces the Motherboard to reset when
an Alive failure occurs.
On error...
Power
OFF
The RAS Board forces the Motherboard to Power Off
when an Alive failure occurs.
Shutdown
Monitoring
timer
Specifies a monitoring time for Shutdown.
If the shutdown process was not completed within the specified
period, the RAS Board detected a Shutdown Failure.
No
Action
No action when the Shutdown failure occurs.
Reset
The RAS Board forces the Motherboard to reset when a
Shutdown failure occurs.
On error...
Power
OFF
The RAS Board forces the Motherboard to Power Off
when a Shutdown Failure occurs.
Note: The Startup Monitoring is active even during the BIOS setup! Therefore, disable the
Startup Monitoring to configure the BIOS settings. With Dip Switch pin no. 8 on the RAS
Board you can disable RAS monitoring functions.
Logging Cycle
Here you configure the logging cycle of the RAS board.
Item
Description
On/Off
Enables/disables the RAS logging.
starts
Specifies a time after the IPC startup for the Initial logging.
at intervals of
Specifies intervals for the periodic logging.
LCD Setting
Item
Description
ON/Off
Enables/disables the LCD Backlight monitoring.
LCD Backlight
Brightness
Selects a level of the LCD backlight brightness among from High, Middle
and Low. Default is High.
Note: For NSA-CPU0x-E models the LCD Backlight monitoring is not supported.