3. Software 

 
The DyaloX IPC is installed with Microsoft® Windows XP Embedded SP2. This modular 
operating system is based on Microsoft® Windows XP Professional. Omron has carefully 
selected the items needed to give you flexibility to run and use many different kinds of 
software, but still be able to give you the best reliable operating system for industrial use.  

3.1  Bios settings 

 
In some occasions it might be needed to change some BIOS settings. All BIOS menus are 
explained in detail in the manual of the DyaloX. Below you find some basic information. 
 
Perform the actions below to enter the BIOS setup menu. 
 
When this message is displayed:  

Press <F2> to enter SETUP. 

 

1. Press the F2 Key while the message box is displayed to launch the setup menu. 

 

2. The Main Setting Screen will be displayed. 
Note: You must enter a password if one has been set. 

 

3. Use the Down, Left, or Right Arrow Key to go to the next item and use the Enter 
Key to select the item. 

 
Select the Exit Screen to exit from the setup menu. 
 
Note: The RAS Board’s startup monitoring is performed (when enabled) even during BIOS 
setup. Disable the Start-up monitoring function when making the BIOS settings. If the startup 
monitoring function cannot be disabled, turn ON pin 8 of the DIP switch to disable the Action 
on Failure function. 

3.1.1  BIOS Setup Menu Keys 

 
BIOS setup items can only be set from a keyboard. The following table lists the keys that are 
available from the BIOS setup utility and how to use them. 
 

Key 

Action  

 

 

Switches menus.  

 

 

Selects the item that will be set.  

-/+ 

Increases or decreases a value.  

Tab 

Moves to the next field.  

Shift + Tab 

Moves to the previous field.  

F1 

Displays the General Help Window for BIOS setup.  

F9 

Loads the default configuration value.  

F10 

Saves the settings to CMOS and exits the BIOS setup utility.  

ESC 

Moves to the Exit Menu or moves to the Main Menu from a Submenu.  

Enter 

Sets a value and moves to a submenu if one is available.  

 

3.1.2  Advanced menu 

 
In the Advanced menu there are some settings you might need or want to use. 
They are explained in the table below. 
 
 

Summary of Contents for DYALOX INDUSTRIAL PC

Page 1: ...Cat No V06 EN 02 DyaloX Industrial PC NSA1_ TX01B E S E NSA1_ TX1_B E S E NSA CPU_ E NSA TY_B S QUICK START GUIDE Cat No V06 EN 02 DyaloX Industrial PC QUICK START GUIDE...

Page 2: ......

Page 3: ...Quick Start Guide DyaloX Industrial PC...

Page 4: ......

Page 5: ...re 7 3 1 Bios settings 7 3 2 Windows XP Embedded 9 3 3 Enhanced Write Filter EWF 9 3 4 Available Tools 10 4 RAS 11 4 1 RAS Functions 11 4 2 RAS Utility software 13 5 Restore image with USB stick 21 Fo...

Page 6: ...em Features of the DyaloX Industrial grade 600MHz or 1 3 GHz Intel Celeron M CPU Disk On Module silicon storage Fan Less heat sink cooling Unique Embedded RAS solution Extended version of Windows XP E...

Page 7: ...3 2 1Specifications of all the DyaloX models...

Page 8: ...4...

Page 9: ...of the male RS 232C connector COM port 1 and 2 Pin No Signal 1 CD Carrier Detect 2 RD Receive 3 SD Send 4 DTR Data Terminal Ready 5 GND Signal ground 6 DSR Data Set Ready 7 RTS Request To Send 8 CTS...

Page 10: ...R FAIL OFF Normally open supplies 24V at PWR FAIL Default setting OFF 7 Always OFF 8 Enables disables actions when the RAS Board detects a Startup Alive Shutdown failure ON Disables the actions OFF En...

Page 11: ...y to select the item Select the Exit Screen to exit from the setup menu Note The RAS Board s startup monitoring is performed when enabled even during BIOS setup Disable the Start up monitoring functio...

Page 12: ...sec 10 sec 6 sec 2 sec Selects the number of times per second to repeat a keystroke when you hold a key down Keyboard auto repeat delay 1 4 sec 1 2 sec 3 4 sec 1 sec Selects the delay time after a ke...

Page 13: ...he Windows XP Professional OS may not operate on the Windows XP Embedded OS of an DyaloX Industrial PC In addition the Windows components cannot be added and deleted by selecting Add or Remove Program...

Page 14: ...it can display an icon in the toolbar Beside this tool there is another way to use the right mouse click by pressing the touch area for a defined time Please contact your local Omron representative i...

Page 15: ...RAS board is able to provide a system snapshot just before failure occurs By analyzing the log data the trend and cause of failures can be quickly found and rectified for higher reliability in the fut...

Page 16: ...Action on Failures forced shut down forced reboot RAS can take action where a failure is detected The following functions are provided Rebooting the system automatically when the operating system free...

Page 17: ...user may export log files to save logs to a file on a regular basis The user may also import log files to compare and analyze past logs with logs currently in the memory or to conduct log analysis on...

Page 18: ...Failure detected A Monitoring failure is detected Error LCD Backlight The LCD backlight has a failure Warning Temperatures The temperatures of the Motherboard exceed the threshold Warning Voltages The...

Page 19: ...ailure Notification OFF Disables the Failure Notification The Main window does not automatically appear even when a failure is detected When you choose View more detail in the menu you will see the fo...

Page 20: ...such as an Alive Error Note You can change a message of the RAS status in RAS Utility Settings Others RAS Utility Toolbar buttons Icon Name Description Open Log File Opens a log data file and displays...

Page 21: ...the RAS board you can view those log files here This window allows you to filter all the log files and even find a specific error in the files Beside the RAS log files it also allows you to view the...

Page 22: ...s Click an icon in the list to show the specific page Icon Page Description Monitoring To configure the Startup Alive Shutdown Monitoring Logging Cycle To configure the Logging Cycle to acquire voltag...

Page 23: ...ard forces the Motherboard to Power Off when an Alive failure occurs Shutdown Monitoring timer Specifies a monitoring time for Shutdown If the shutdown process was not completed within the specified p...

Page 24: ...res of the Motherboard UPS To configure settings at the time of the Power Failure Signal detection from the UPS Others To configure messages for errors and the status refresh cycle For the Threshold s...

Page 25: ...the DyaloX IPC 2 When you see the message Press F2 to enter SETUP press F2 3 Select the Boot menu 4 Select Hard Drive and press Enter 5 Now you see a list of drives In this list you should also see t...

Reviews: