6
Introducing the Function Blocks
Section 1-1
Main Popup Menus
Popup Menu for Function Block Definitions
Popup Menu for Inserted Function Blocks
Popup Menu for Function Block Variable Tables
Popup Menu for Instances
Shortcut Keys
F Key: Pasting Function
Block Definitions in
Program
Move the cursor to the position at which to create the copied function block
instance in the Ladder Section Window, and click the
F
Key. This operation is
the same as selecting
Insert - Function Block Invocation.
P Key: Inputting
Parameters
Position the cursor at the left of the input variable, or at the right of the output
variable and click the
P
Key. This operation is the same as selecting
Insert -
Function Block Parameter.
Popup menu
Function
Insert Function Block
Ladder
Creates a function block definition with a ladder programming language algo-
rithm.
Structured Text
Creates a function block definition with an ST language algorithm.
From file
Reads a function block definition from a function block library file (*.cxf).
Popup menu
Function
Open
Displays the contents of the selected function block definition on the right side of the window.
Save Function Block File
Saves the selected function block definition in a file.
Compile
Compiles the selected function block definition.
Popup menu
Function
Edit
Edits the variable.
Insert Variable
Adds a variable to the last line.
Insert Variable
Above
Inserts the variable above the current cursor position.
Below
Inserts the variable below the current cursor position.
Cut
Cuts the variable.
Copy
Copies the variable.
Paste
Pastes the variable.
Find
Searches for the variable. Variable names, variable comments, or all (text strings) can
be searched.
Replace
Replaces the variable.
Delete
Deletes the variable.
Rename
Changes only the name of the variable.
Popup menu
Function
Edit
Changes the instance name.
Update Invocation
When a function block definition’s I/O variables have been changed after the instance
was created, an error will be indicated by displaying the instance’s left bus bar in red.
This command updates the instance with the new information and clears the error.
Go To Function Block Definition Displays the selected instance’s function block definition on the right side of the window.
Summary of Contents for CS1-H Series
Page 3: ...iv...
Page 5: ...vi...
Page 7: ...viii TABLE OF CONTENTS...
Page 15: ...xvi Application Precautions 4...
Page 151: ...136 Procedures Section 3 2...
Page 153: ...138 Data Types Appendix A...
Page 177: ...162 External Variables Appendix C...
Page 181: ...166 Revision History...