![Omron CS1-H Series Operation Manual Download Page 117](http://html1.mh-extra.com/html/omron/cs1-h-series/cs1-h-series_operation-manual_742526117.webp)
102
Instruction Support and Operand Restrictions
Section 2-6
REPLACE IN
STRING
RPLC$
@RPLC$
661
S1: Text string first
word
UINT
Yes (not
fixed)
S2: Replacement
text string first word
UINT
Yes (not
fixed)
S3: Number of
characters
UINT
---
S4: Beginning posi-
tion
UINT
---
D: First destination
word
UINT
Yes (not
fixed)
DELETE STRING
DEL$
@DEL$
658
S1: Text string first
word
UINT
Yes (not
fixed)
S2: Number of
characters
UINT
---
S3: Beginning posi-
tion
UINT
---
D: First destination
word
UINT
Yes (not
fixed)
EXCHANGE
STRING
XCHG$
@XCHG$
665
Ex1: 1st exchange
word 1
UINT
Yes (not
fixed)
Ex2: 1st exchange
word 2
UINT
Yes (not
fixed)
CLEAR STRING
CLR$
@CLR$
666
S: Text string first
word
UINT
Yes (not
fixed)
INSERT INTO
STRING
INS$
@INS$
657
S1: Base text string
first word
UINT
Yes (not
fixed)
S2: Inserted text
string first word
UINT
Yes (not
fixed)
S3: Beginning posi-
tion
UINT
---
D: First destination
word
UINT
Yes (not
fixed)
String Comparison
LD,AND, OR
+
=$,<>$,<$,<
=$,>$,>=$
670 (=$)
671 (<>$)
672 (<$)
673 (<=$)
674 (>$)
675 (>=$)
S1: Text string 1
UINT
Yes (not
fixed)
S2: Text string 2
UINT
Yes (not
fixed)
Instruction
Mnemonic
Function
code
Symbol
Operands
Supported
variable
data types
AT
setting or
array
variable
required
(Required
word data
size
shown in
parenthe-
ses.)
RPLC$
S1
S2
S3
S4
D
DEL$
S1
S2
S3
D
XCHG$
Ex1
Ex2
CLR$
S
INS$
S1
S2
S3
D
Symbol
S1
S2
Summary of Contents for CS1-H Series
Page 3: ...iv...
Page 5: ...vi...
Page 7: ...viii TABLE OF CONTENTS...
Page 15: ...xvi Application Precautions 4...
Page 151: ...136 Procedures Section 3 2...
Page 153: ...138 Data Types Appendix A...
Page 177: ...162 External Variables Appendix C...
Page 181: ...166 Revision History...