7. Connection Procedure
7
The PCU Setting Window is
displayed. Select
Network
Setting
from the project tree on
the left side of the Window.
Confirm that
#17_New Slave
E3NW-ECT Communication Unit
for Digital Type Sensor 60
inputs(V1.0)
was added.
*The model and version may differ
depending on the device used.
8
Click the Remote I/O Input/Output
Memory Area Allocation List Tab
that is on the right side on the PCU
Parameter Setting Window.
Confirm that node address #17 is
displayed and the I/O Memory
Areas are set as follows:
•Input offset: 0
•Input address: 3900
•Input size: 10 bytes
•Output offset: -
•Output address: -
•Output size: 0 byte
9
Select
Verify Network
from the
Network Menu.
10
Confirm that
Matched
is displayed
on the Network Verification Result
Dialog Box, and click the
OK
Button.
22