7. Connection Procedure
7
Check the display contents of the
Fiber Amplifier.
The LED indicators in the figure on
the right show as follows:
Outputs of Sensor unit No. 1
IN2[2]: Lit orange (ON)
IN1[1]: Lit orange (ON)
*They are the outputs of the Fiber
Amplifier connected to the Digital
Sensor Communication Unit.
Outputs of Sensor unit No. 2
IN2[2]: Lit orange (ON)
IN1[1]: Lit orange (ON)
*They are the outputs of the Fiber
Amplifier connected to the
Distributed Sensor Unit.
Digital Sensor Communication Unit and Fiber
Amplifier (Sensor unit No. 1)
Distributed Sensor Unit and Fiber Amplifier
(Sensor unit No. 2)
8
Enter 3900 in the Start Address
Field on the CIO Window.
Confirm that the start address was
changed to 3900.
The right example shows as follows:
CIO 3900: 000F (IN1 and IN2 of
Sensor unit No. 1 and 2
are turned ON.)
CIO 3902: 0200 (BUSY: OFF,
S_ERR: OFF, Number of
Sensors setting: 2)
CIO 3903: 0002
(Number of Sensors: 2)
Fiber Amplifier
Digital Sensor Communication Unit
Distributed Sensor Unit
IN2
IN1
IN2
IN1
Fiber Amplifier
28
Summary of Contents for CJ1W-NC82
Page 35: ...32...