29
Multi-function input 1
selection
1103h
C001
1401h
C001
2nd multi-function input 1
selection
1532h
C201
Multi-function input 2
selection
1104h
C002
1402h
C002
2nd multi-function input 2
selection
1533h
C202
Multi-function input 3
selection
1105h
C003
1403h
C003
2nd multi-function input 3
selection
1534h
C203
Multi-function input 4
selection
1106h
C004
1404h
C004
2nd multi-function input 4
selection
1535h
C204
Multi-function input 5
selection
1107h
C005
1405h
C005
2nd multi-function input 5
selection
1536h
C205
Multi-function input 1
110Bh
C011
140Bh
C011
Multi-function input 2
110Ch
C012
140Ch
C012
Multi-function input 3
110Dh
C013
140Dh
C013
Multi-function input 4
110Eh
C014
140Eh
C014
Multi-function input 5
110Fh
C015
140Fh
C015
00: FW
01: RV
02: CF1
03: CF2
04:CF3
05: CF4
06: JG
07: DB
08: SET
09: 2CH
11: FRS
12: EXT
13: USP
15: SFT
16: AT
18: RS
19: PTC terminal 5 only
20: STA
2+1: STP
22: F/R
23: PID
24: PIDC
27: UP
28: DWN
29: UDC
31: OPE
50: ADD
51: F-TM
52: RDY
53: SP-SET
64: EMR(automatically allocated to
terminal 3 if enabled)
255: NO
-
00: FW (Forward)
01: RV (Reverse)
02: CF1 (Multi-step speed setting
binary 1)
03: CF2 (Multi-step speed setting
binary 2)
04: CF3 (Multi-step speed setting
binary 3)
05: CF4 (Multi-step speed setting
binary 4)
06: JG (Jogging)
07: DB (External DC injection
braking)
08: SET (2nd control)
09: 2CH (2-step
acceleration/deceleration)
11: FRS (Free-run stop)
12: EXT (External trip)
13: USP (Power recovery restart
prevention function)
14: CS (Commercial switch)
15: SFT (Soft lock)
16: AT (Analog input switching)
18: RS (reset)
19: TH (PTC thermistor thermal
protection)
<C005 only>
20: STA (3-wire start)
21: STP (3-wire stop)
22: F/R (3-wire forward/reverse)
23: PID (PID disabled)
24: PIDC (PID integral reset)
27: UP (Remote operation
accelerated)
28: DWN (Remote operation
decelerated)
29: UDC (Remote operation data
clear)
31: OPE (Forced operator function)
32: SF1 (Multi-step speed setting bit
1)
33: SF2 (Multi-step speed setting bit
2)
34: SF3 (Multi-step speed setting bit
3)
35: SF4 (Multi-step speed setting bit
4)
36: SF5 (Multi-step speed setting bit
5)
37: SF6 (Multi-step speed setting bit
6)
38: SF7 (Multi-step speed setting bit
7)
39: OLR (Overload limit switching)
40: TL (Torque limit enabled)
41: TRQ1 (Torque limit switching 1)
42: TRQ2 (Torque limit switching 2)
44: BOK (Brake confirmation)
46: LAC (LAD cancel)
47: PCLR (Current position clear)
50: ADD (Set frequency A145
addition)
51: F-TM (Forced terminal block)
52: ATR (Torque reference input
permission)
53: KHC (Integrated power clear)
56: MI1 (General-purpose input 1)
57: MI2 (General-purpose input 2)
58: MI3 (General-purpose input 3)
-
00︓NO
01︓NC
-
00: NO (NO contact)
01: NC (NC contact)
-