background image

25 

Frequency reference

selection

1019h

A001

00: Digital Operator (volume)

01: Terminal

02: Digital Operator (F001)

03: ModBus communication

10: Frequency operation result

-

1201h

A001

00: Volume

01: Control circuit terminal block

(Analog input)

02: Digital Operator

03: Modbus communication

04: Option

06: Pulse train frequency

07: DriveProgramming

10: Operation function output

-

RUN command selection

101Ah

A002

01: Terminal

02: Digital Operator

03: ModBus communication

-

1202h

A002

01: Control circuit terminal block

(DriveProgramming)

02: Digital Operator

03: Modbus communication

04: Option

-

Base frequency

101Bh

A003

30. to maximum frequency A004

1203h

A003

300 to 1st Maximum Frequency

2nd base frequency

150Ch

A203

30. to maximum frequency A204

2203h

A203

300 to 2nd Maximum Frequency

Maximum frequency

101Ch

A004

1204h

A004

1st Base Frequency to 4000 (In the

high-frequency mode︓~5800)

2nd maximum frequency

150Dh

A204

2204h

A204

1st Base Frequency to 4000 (In the

high-frequency mode︓~5800)

FV/FI selection

101Dh

A005

02: Switches between FV/VR via

terminal AT

03: Switches between FI/VR via

terminal AT

04: Terminal FV

05: Terminal FI

-

1205h

A005

00: Switch between FV and FI

02: Switch between FV and volume

03: Switch between FI and volume

-

120Bh A011(HIGH)

120Ch A011(LOW)

120Dh A012(HIGH)

120Eh A012(LOW)

FV start ratio

1023h

A013

120Fh

A013

FV end ratio

1024h

A014

1210h

A014

FV start selection

1025h

A015

00: Start frequency A011

01: 0 Hz

-

1211h

A015

00: FV Start Frequency (A011)

01: 0 Hz

-

FV, FI sampling

1026h

A016

1 ~ 17

-

1212h

A016

1 to 30/31 (500-ms filter with ±0.1-

Hz hysteresis)

1

1216h A020(HIGH)
1217h A020(LOW)
2216h A220(HIGH)
2217h A220(LOW)
1218h A021(HIGH)

1219h A021(LOW)

121Ah A022(HIGH)

121Bh A022(LOW)

121Ch A023(HIGH)

121Dh A023(LOW)

121Eh A024(HIGH)

121Fh A024(LOW)

1220h A025(HIGH)

1221h A025(LOW)

1222h A026(HIGH)

1223h A026(LOW)

1224h A027(HIGH)

1225h A027(LOW)

1226h A028(HIGH)

1227h A028(LOW)

1228h A029(HIGH)

1229h A029(LOW)

122Ah A030(HIGH)

122Bh A030(LOW)

122Ch A031(HIGH)

122Dh A031(LOW)

122Eh A032(HIGH)

122Fh A032(LOW)

1230h A033(HIGH)

1231h A033(LOW)

1232h A034(HIGH)

1233h A034(LOW)

1234h A035(HIGH)

1235h A035(LOW)

Jogging frequency

1048h

A038

0 ~ 999

0.01[Hz]

1238h

A038

Starting Frequency to 999 (In the

high-frequency mode︓10000)

0.01[Hz]

Jogging stop selection

1049h

A039

00: Free-run stop

01: Deceleration stop

02: DC injection braking stop

-

1239h

A039

00: Free-running on jogging stop/

Disabled during operation

01: Deceleration stop on jogging

stop/ Disabled during operation

02: DC injection braking on jogging

stop/Disabled during operation

03: Free-running on jogging stop/

Enabled during operation

04: Deceleration stop on jogging

stop/ Enabled during operation

05: DC injection braking on jogging

stop/ Enabled during operation

-

Torque boost selection

104Ah

A041

123Bh

A041

2nd torque boost selection

1510h

A241

223Bh

A241

Manual torque boost voltage 104Bh

A042

123Ch

A042

2nd manual torque boost

1511h

A242

223Ch

A242

Manual torque boost

104Ch

A043

123Dh

A043

2nd manual torque boost

1512h

A243

223Dh

A243

V/f characteristics selection

104Dh

A044

123Eh

A044

2nd V/f characteristics

selection

1513h

A244

223Eh

A244

0 ~ 500

0.1[%]

0~500

0.1[%]

00: VC

01: 1.7th power of VP

06: Special VP

-

00: Constant torque characteristics

01: Reduced torque characteristics

02: Free V/f setting

-

00: Manual torque boost only

01: Simple torque boost

-

00: Manual torque boost

01: Automatic torque boost

-

0 ~ 200

0.1[%]

0~200

0.1[%]

Multi-step speed reference

14

1045h

A034

Multi-step speed reference

15

1047h

A035

Multi-step speed reference

12

1041h

A032

Multi-step speed reference

13

1043h

A033

Multi-step speed reference

10

103Dh

A030

Multi-step speed reference

11

103Fh

A031

Multi-step speed reference 8 1039h

A028

Multi-step speed reference 9 103Bh

A029

Multi-step speed reference 6 1035h

A026

Multi-step speed reference 7 1037h

A027

A023

Multi-step speed reference 4 1031h

A024

Multi-step speed reference 5 1033h

A025

0 ~ 100

1[%]

0~100

1[%]

0.01[Hz]

2nd multi-step speed

reference 0

150Fh

A220

0

Starting Frequency to 2nd Maximum

Frequency

Multi-step speed reference 1 102Bh

A021

0

Starting frequency to Maximum

frequency

Multi-step speed reference 2

Multi-step speed reference 0 1029h

A020

0.0/Starting frequency to 4000

0.1[Hz]

0

Starting Frequency to 1st Maximum

Frequency

102Dh

A022

Multi-step speed reference 3 102Fh

1[Hz]

0.1[Hz]

30 ~ 400

1[Hz]

0.1[Hz]

FV start frequency

1020h

A011

0 ~ 4000

0.1[Hz]

0~40000

(In the high-frequency mode︓~

58000)

0.01[Hz]

FV end frequency

1022h

A012

Summary of Contents for 3G3JX

Page 1: ...Simple Compact Inverters JX series Replace Guide From 3G3JX to 3G3MX2 3G3MX2 A 3G3JX A I924 E1 01...

Page 2: ...ith respect to the use of the information contained herein Moreover because OMRON is constantly striving to improve its high quality products the information contained in this manual is subject to cha...

Page 3: ...afe use and precautions for correct use Intended Audience This guide is intended for the following personnel Personnel in charge of introducing control equipment Personnel in charge of designing contr...

Page 4: ...ity or the results from the use of Products in combination with any electrical or electronic components circuits system assemblies or any other materials or substances or environments Any advice recom...

Page 5: ...Liability Change in Specifications Product specifications and accessories may be changed at any time based on improvements and other reasons It is our practice to change part numbers when published r...

Page 6: ...derstand the manuals for all devices and equipment that will make up the system to ensure that the system is used safely Review the entire contents of these manuals including all safety precautions pr...

Page 7: ...to install and wire the inverter set parameters needed to operate the inverter and remedies to be taken and inspection methods to be used in case that problems occur 3G3MX2 Series Type V1 Multi functi...

Page 8: ...History A manual revision code appears as a suffix to the catalog number on the front and back covers of the manual Revision code Date Revised content 01 July 2019 Original production Cat No I924 E1 0...

Page 9: ...al Dimensions 13 4 Arrangement and Function of Terminal Block 17 4 1 Control Circuit Terminal Block 17 5 Functional difference 19 5 1 Dual duty rating 19 5 2 Modbus communication 19 6 Parameter List 2...

Page 10: ...10 1 Target model 1 Replaced old model 3G3JX series Compact Simplified Inverter 3G3JX 2 New model 3G3MX2 Series Type V1 Multi function Compact Inverter 3G3MX2 V1...

Page 11: ...ferences between 3G3JX and 3G3MX2 V1 in default parameter values and parameter functions refer to this guide For details of functions refer to related product user s manuals at the time of setting 6 T...

Page 12: ...140 128 170 5 0 0 4 5 A2055 180 250 169 4 164 235 6 A2055 V1 140 260 155 0 0 6 A2075 180 250 169 4 164 235 6 A2075 V1 140 260 155 0 0 6 3 phase 400 V class 3G3JX Series 3G3MX2 V1 Series Model 3G3JX D...

Page 13: ...V1 3 phase 200 V input specifications 2 When using 3G3JX AE with single phase 200 V input select from 3G3MX2 V1 single phase 200 V input specifications 3 2 External Dimensions 3G3JX Series 3G3MX2 V1 S...

Page 14: ...s Model 3G3JX D mm D1 mm D2 mm A4004 130 5 28 2 6 AE007 A2015 157 5 55 6 A2022 A4007 A4015 A4022 AE015 AE022 Model 3G3MX2 D mm D1 mm A4004 V1 143 5 28 A2015 V1 170 5 55 A2022 V1 A4007 V1 A4015 V1 A402...

Page 15: ...15 3G3JX Series 3G3MX2 V1 Series Model 3G3JX A2037 A4037 Model 3G3MX2 A2037 V1 A4040 V1...

Page 16: ...16 3G3JX Series 3G3MX2 V1 Series Model 3G3JX A2055 A2075 A4055 A4075 Model 3G3MX2 A2055 V1 A2075 V1 A4055 V1 A4075 V1...

Page 17: ...ared with the safety input When the safety function selector switch is ON S3 and S4 are automatically set to safety input GS1 GS2 S5 Multi function input S5 TH Multi function input External thermistor...

Page 18: ...1 Multi function output terminal Safety monitor terminal used in common This terminal is automatically set to P1 EDM Safety monitor signal when the EDM function selector switch is turned ON PC Output...

Page 19: ...torque during acceleration and deceleration Light load VT This mode is for a fan pump or other device that operates at the rated motor torque or lower With a load tolerance of 120 of rated torque min...

Page 20: ...rameter arrangement parameter name and default value There are some difference of Parameter name settings number date range and arrangement between 3G3JX and 3G3MX2 V1 Before setting to refer this sec...

Page 21: ...nd control 9 2CH 2 step acceleration deceleration 2CH 2 step acceleration deceleration 11 FRS free run stop FRS Free run stop 12 EXT external trip EXT External trip 13 USP USP function UPS Power recov...

Page 22: ...3MX2 V1 Data No Code Function name Code Function name 0 RUN signal during RUN RUN Signal during RUN 1 FA1 constant speed arrival signal FA1 Constant speed arrival signal 2 FA2 over set frequency arriv...

Page 23: ...008h 0008h 0007h Multi function Input 3 0009h 0009h 0008h Multi function Input 4 000Ah 000Ah 0009h Multi function Input 5 000Bh 000Bh 000Ah Operation status 1 Run 0 Stop Interlocked with d003 000Eh 00...

Page 24: ...01Ch Fault Monitor 1 Fault 001Dh Fault Monitor 1 Inverter Status 001Eh 0 40000 LOW 001Fh 0 58000 HIGH 0020h Trip monitor 2 Current 0 1 A 0020h Output Current 0 01 A 0021h Trip monitor 2 Voltage 1 V 00...

Page 25: ...1048h A038 0 999 0 01 Hz 1238h A038 Starting Frequency to 999 In the high frequency mode 10000 0 01 Hz Jogging stop selection 1049h A039 00 Free run stop 01 Deceleration stop 02 DC injection braking...

Page 26: ...rgy saving operation 126Dh A085 00 Normal operation 01 Energy saving operation Energy saving response 1073h A086 0 1000 0 1 126Eh A086 0 1000 0 1 1074h A092 MSB 1274h A092 HIGH 1075h A092 LSB 1275h A0...

Page 27: ...8 200 2000 0 1 Soft lock selection 10BCh b031 00 Data other than b031 cannot be changed when terminal SFT is ON 01 Data other than b031 and the specified frequency parameter cannot be changed when ter...

Page 28: ...restart 01 Frequency matching restart 02 Frequency pull in restart Stop selection 10DAh b091 00 Deceleration Stop 01 Free run stop 135Eh b091 00 Deceleration stop 01 Free run stop Cooling fan control...

Page 29: ...nary 3 05 CF4 Multi step speed setting binary 4 06 JG Jogging 07 DB External DC injection braking 08 SET 2nd control 09 2CH 2 step acceleration deceleration 11 FRS Free run stop 12 EXT External trip 1...

Page 30: ...4 OD 05 AL 06 Dc 07 FBV 08 NDc 09 LOG 10 ODc Do not use 43 LOC 00 RUN During RUN 01 FA1 Constant speed arrival signal 02 FA2 Set frequency exceeded signal 03 OL Overload warning 04 OD Excessive PID de...

Page 31: ...delay 1153h C144 1486h C130 Output terminal P1 OFF 1154h C145 1487h C131 Relay output ON delay 1157h C148 1490h C140 Relay output OFF delay 1158h C149 1491h C141 Motor capacity selection 1165h H003 15...

Page 32: ...2019 0919 0919 I924 E1 01 Note Do not use this document to operate the Unit...

Reviews: