24 

 

7.2.

 

Register Number 

In 3G3MX2-V1, (Register address)

=(

Register number

)-

 

Register

No.

Parameter

No.

Monitor or setting data

Data

resolution

Register

No.

Parameter

No.

Monitor or setting data

Data

resolution

0001h F001(HIGH)

0002h F001(LOW)

Inverter status

0003h

-

00: Default

02: Stop

03: Run

04: Free-run stop (FRS)

05: Jogging

06: DC injection braking

07: Retry

08: Trip

09: Undervoltage

-

0003h

-

0: Initial status

2: Stop

3: Run

4: Free-run stop

5: Jogging

6: DC injection

braking

8: Trip

9: During UV

-

PID feedback

(Enable when A076 = 02)

0005h

-

0 ~ 1000

0.1[%]

0006h

-

0~10000

0.01[%]

1001h d001(HIGH)

1002h d001(LOW)

Output current monitor

1003h

d002

0 ~ 2000

0.1[%]

1003h

d002

0~65530

0.01[A]

Rotation direction monitor

1004h

d003

00: Stop

01: Forward

02: Reverse

-

1004h

d003

0: Stop

1: Forward

2: Reverse

-

1005h d004(MSB)

1005h d004(HIGH)

1006h d004(LSB)

1006h d004(LOW)

Multi-function input monitor

1007h

d005

0 to 63

Multi-function input status, Bit 0 =

[1] to Bit 4 = [5]

-

1007h

d005

2

0

︓Terminal S1

~2

6

︓Terminal S7/EB

ビット

Multi-function output

monitor

1008h

d006

0 to 7

Multi-function output status,

Bit 0 = [P1]

Bit 1 = Not used.

Bit 2 = [MA]

-

1008h

d006

2

0

  ︓Terminal P1

~2

1

︓Terminal P2

2

6

  ︓Relay output terminal MA

ビット

1009h d007(MSB)

1009h d007(HIGH)

100Ah d007(LSB)

100Ah d007(LOW)

Output voltage monitor

100Ch

d013

0 ~ 20000

0.01[%]

1011h

d013

0~6000

0.1[V]

100Eh d016(MSB)

1015h d016(HIGH)

100Fh d016(LSB)

1016h d016(LOW)

1010h d017(MSB)

1017h d017(HIGH)

1011h d017(LSB)

1018h d017(LOW)

Fin temperature monitor

116Ah

d018

0 ~ 2000

0.1[ ℃ ]

1019h

d018

-200~+1500

0.1[°C]

Fault frequency monitor

0011h

d080

0 ~ 65535

-

0011h

d080

0~65535

1[回]

DC voltage monitor

116Ch

d102

0 ~ 9999

0.1[V]

1026h

d102

0~10000

0.1[V]

Electronic thermal monitor

116Dh

d104

0 ~ 1000

0.1[%]

1028h

d104

0~1000

0.1[%]

0012h

Fault Monitor 1 Fault

0013h

Fault Monitor 1 Inverter

0014h

0~40000(LOW)

0015h

0~58000(HIGH)

0016h

Trip monitor 1: Current

0.1[A]

0016h

Output Current

0.01[A]

0017h

Trip monitor 1: Voltage

1[V]

0017h

DC Voltage

0.1[V]

0018h

Trip monitor 1: Run time (MSB)

0018h

Total RUN Time (HIGH)

0019h

Trip monitor 1: Run time (LSB)

0019h

Total RUN Time (LOW)

001Ah

Trip monitor 1: ON time (MSB)

001Ah

Total Power ON Time (HIGH)

001Bh

Trip monitor 1: ON time (LSB)

001Bh

Total Power ON Time (LOW)

001Ch

Fault Monitor 1 Fault

001Dh

Fault Monitor 1 Inverter

Status

001Eh

0~40000(LOW)

001Fh

0~58000(HIGH)

0020h

Trip monitor 2: Current

0.1[A]

0020h

Output Current

0.01[A]

0021h

Trip monitor 2: Voltage

1[V]

0021h

DC Voltage

0.1[V]

0022h

Trip monitor 2: Run time (MSB)

0022h

Total RUN Time (HIGH)

0023h

Trip monitor 2: Run time (LSB)

0023h

Total RUN Time (LOW)

0024h

Trip monitor 2: ON time (MSB)

0024h

Total Power ON Time (HIGH)

0025h

Trip monitor 2: ON time (LSB)

0025h

Total Power ON Time (LOW)

0026h

Fault Monitor 1 Fault

0027h

Fault Monitor 1 Inverter

0028h

0~40000(LOW)

0029h

0~58000(HIGH)

002Ah

Trip monitor 3: Current

0.1[A]

002Ah

Output Current

0.01[A]

002Bh

Trip monitor 3: Voltage

1[V]

002Bh

DC Voltage

0.1[V]

002Ch

Trip monitor 3: Run time (MSB)

002Ch

Total RUN Time (HIGH)

002Dh

Trip monitor 3: Run time (LSB)

002Dh

Total RUN Time (LOW)

002Eh

Trip monitor 3: ON time (MSB)

002Eh

Total Power ON Time (HIGH)

002Fh

Trip monitor 3: ON time (LSB)

002Fh

Total Power ON Time (LOW)

1014h F002(MSB)

1103h F002(HIGH)

1015h F002(LSB)

1104h F002(LOW)

1501h F202(MSB)

2103h F202(HIGH)

1502h F202(LSB)

2104h F202(LOW)

1016h F003(MSB)

1105h F003(HIGH)

1017h F003(LSB)

1106h F003(LOW)

1503h F203(MSB)

2105h F203(HIGH)

1504h F203(LSB)

2106h F203(LOW)

Operator rotation direction

selection

1018h

F004

0: Forward

1: Reverse

-

1107h

F004

00: Forward

01: Reverse

-

Acceleration time 1

1 to 300000

The second decimal place is ignored

when the value is over 10000 (100.0

seconds).

0.01[s]

0~360000

0.01[s]

2nd acceleration time 1

Deceleration time 1

2nd deceleration time 1

0.1[Hz]

0.01[Hz]

1[h]

1[h]

1[h]

1[h]

Fault monitor 3

0026h

d083

Trip monitor 3: Factor code

-

d083

-

0028h

Trip monitor 3: Frequency

-

001Eh

Trip monitor 2: Frequency

0.1[Hz]

0.01[Hz]

1[h]

1[h]

Fault monitor 2

001Ch

d082

Trip monitor 2: Factor code

-

d082

1[h]

1[h]

Power ON time monitor

0 ~ 999999

1[h]

0~999000

1[h]

Fault monitor 1

0012h

d081

Trip monitor 1: Factor code

-

d081

-

0014h

Trip monitor 1: Frequency

0.1[Hz]

0.01[Hz]

1[h]

1[h]

1[h]

1[h]

Output frequency monitor

(after conversion)

0 ~ 3996000

0.01

0~3999600 (In the high-frequency

mode︓~5799420)

0.01

Total RUN time

0 ~ 999999

1[h]

0~999000

1[h]

0.01[Hz]

PID feedback value monitor

(A075 PID scale)

0 ~ 999900

0.01[%]

0~100000

0.1

Output frequency monitor

1002h

d001

0 ~ 4000

0.1[Hz]

0~40000 (In the high-frequency

mode︓~58000)

Function name

3G3JX

3G3MX2-V1

Frequency reference

(Enable when A001 = 03)

0002h

-

0 ~ 4000

0.1[Hz]

0 to Maximum frequency

0.01[Hz]

 

Summary of Contents for 3G3JX

Page 1: ...Simple Compact Inverters JX series Replace Guide From 3G3JX to 3G3MX2 3G3MX2 A 3G3JX A I924 E1 01...

Page 2: ...ith respect to the use of the information contained herein Moreover because OMRON is constantly striving to improve its high quality products the information contained in this manual is subject to cha...

Page 3: ...afe use and precautions for correct use Intended Audience This guide is intended for the following personnel Personnel in charge of introducing control equipment Personnel in charge of designing contr...

Page 4: ...ity or the results from the use of Products in combination with any electrical or electronic components circuits system assemblies or any other materials or substances or environments Any advice recom...

Page 5: ...Liability Change in Specifications Product specifications and accessories may be changed at any time based on improvements and other reasons It is our practice to change part numbers when published r...

Page 6: ...derstand the manuals for all devices and equipment that will make up the system to ensure that the system is used safely Review the entire contents of these manuals including all safety precautions pr...

Page 7: ...to install and wire the inverter set parameters needed to operate the inverter and remedies to be taken and inspection methods to be used in case that problems occur 3G3MX2 Series Type V1 Multi functi...

Page 8: ...History A manual revision code appears as a suffix to the catalog number on the front and back covers of the manual Revision code Date Revised content 01 July 2019 Original production Cat No I924 E1 0...

Page 9: ...al Dimensions 13 4 Arrangement and Function of Terminal Block 17 4 1 Control Circuit Terminal Block 17 5 Functional difference 19 5 1 Dual duty rating 19 5 2 Modbus communication 19 6 Parameter List 2...

Page 10: ...10 1 Target model 1 Replaced old model 3G3JX series Compact Simplified Inverter 3G3JX 2 New model 3G3MX2 Series Type V1 Multi function Compact Inverter 3G3MX2 V1...

Page 11: ...ferences between 3G3JX and 3G3MX2 V1 in default parameter values and parameter functions refer to this guide For details of functions refer to related product user s manuals at the time of setting 6 T...

Page 12: ...140 128 170 5 0 0 4 5 A2055 180 250 169 4 164 235 6 A2055 V1 140 260 155 0 0 6 A2075 180 250 169 4 164 235 6 A2075 V1 140 260 155 0 0 6 3 phase 400 V class 3G3JX Series 3G3MX2 V1 Series Model 3G3JX D...

Page 13: ...V1 3 phase 200 V input specifications 2 When using 3G3JX AE with single phase 200 V input select from 3G3MX2 V1 single phase 200 V input specifications 3 2 External Dimensions 3G3JX Series 3G3MX2 V1 S...

Page 14: ...s Model 3G3JX D mm D1 mm D2 mm A4004 130 5 28 2 6 AE007 A2015 157 5 55 6 A2022 A4007 A4015 A4022 AE015 AE022 Model 3G3MX2 D mm D1 mm A4004 V1 143 5 28 A2015 V1 170 5 55 A2022 V1 A4007 V1 A4015 V1 A402...

Page 15: ...15 3G3JX Series 3G3MX2 V1 Series Model 3G3JX A2037 A4037 Model 3G3MX2 A2037 V1 A4040 V1...

Page 16: ...16 3G3JX Series 3G3MX2 V1 Series Model 3G3JX A2055 A2075 A4055 A4075 Model 3G3MX2 A2055 V1 A2075 V1 A4055 V1 A4075 V1...

Page 17: ...ared with the safety input When the safety function selector switch is ON S3 and S4 are automatically set to safety input GS1 GS2 S5 Multi function input S5 TH Multi function input External thermistor...

Page 18: ...1 Multi function output terminal Safety monitor terminal used in common This terminal is automatically set to P1 EDM Safety monitor signal when the EDM function selector switch is turned ON PC Output...

Page 19: ...torque during acceleration and deceleration Light load VT This mode is for a fan pump or other device that operates at the rated motor torque or lower With a load tolerance of 120 of rated torque min...

Page 20: ...rameter arrangement parameter name and default value There are some difference of Parameter name settings number date range and arrangement between 3G3JX and 3G3MX2 V1 Before setting to refer this sec...

Page 21: ...nd control 9 2CH 2 step acceleration deceleration 2CH 2 step acceleration deceleration 11 FRS free run stop FRS Free run stop 12 EXT external trip EXT External trip 13 USP USP function UPS Power recov...

Page 22: ...3MX2 V1 Data No Code Function name Code Function name 0 RUN signal during RUN RUN Signal during RUN 1 FA1 constant speed arrival signal FA1 Constant speed arrival signal 2 FA2 over set frequency arriv...

Page 23: ...008h 0008h 0007h Multi function Input 3 0009h 0009h 0008h Multi function Input 4 000Ah 000Ah 0009h Multi function Input 5 000Bh 000Bh 000Ah Operation status 1 Run 0 Stop Interlocked with d003 000Eh 00...

Page 24: ...01Ch Fault Monitor 1 Fault 001Dh Fault Monitor 1 Inverter Status 001Eh 0 40000 LOW 001Fh 0 58000 HIGH 0020h Trip monitor 2 Current 0 1 A 0020h Output Current 0 01 A 0021h Trip monitor 2 Voltage 1 V 00...

Page 25: ...1048h A038 0 999 0 01 Hz 1238h A038 Starting Frequency to 999 In the high frequency mode 10000 0 01 Hz Jogging stop selection 1049h A039 00 Free run stop 01 Deceleration stop 02 DC injection braking...

Page 26: ...rgy saving operation 126Dh A085 00 Normal operation 01 Energy saving operation Energy saving response 1073h A086 0 1000 0 1 126Eh A086 0 1000 0 1 1074h A092 MSB 1274h A092 HIGH 1075h A092 LSB 1275h A0...

Page 27: ...8 200 2000 0 1 Soft lock selection 10BCh b031 00 Data other than b031 cannot be changed when terminal SFT is ON 01 Data other than b031 and the specified frequency parameter cannot be changed when ter...

Page 28: ...restart 01 Frequency matching restart 02 Frequency pull in restart Stop selection 10DAh b091 00 Deceleration Stop 01 Free run stop 135Eh b091 00 Deceleration stop 01 Free run stop Cooling fan control...

Page 29: ...nary 3 05 CF4 Multi step speed setting binary 4 06 JG Jogging 07 DB External DC injection braking 08 SET 2nd control 09 2CH 2 step acceleration deceleration 11 FRS Free run stop 12 EXT External trip 1...

Page 30: ...4 OD 05 AL 06 Dc 07 FBV 08 NDc 09 LOG 10 ODc Do not use 43 LOC 00 RUN During RUN 01 FA1 Constant speed arrival signal 02 FA2 Set frequency exceeded signal 03 OL Overload warning 04 OD Excessive PID de...

Page 31: ...delay 1153h C144 1486h C130 Output terminal P1 OFF 1154h C145 1487h C131 Relay output ON delay 1157h C148 1490h C140 Relay output OFF delay 1158h C149 1491h C141 Motor capacity selection 1165h H003 15...

Page 32: ...2019 0919 0919 I924 E1 01 Note Do not use this document to operate the Unit...