Omnitronix DL100 User’s Manual
Page 30
… Alarm
n
: Message
sets the message string to be delivered via serial port 2 during a serial
action for this alarm.
… Alarm
n
: Clear This Alarm Counter Now
allows the administrator to clear the counter for
the selected data alarm manually.
Data Alarm
n
Settings: Setup Alarm Fields
brings up the alarm field selection menu. This
menu contains the settings for up to 16 different field definitions.
Data-Link DL100 - Data Alarm Field Definition Table
Start Length Name
A) 6 4 Err_no
B) 12 10 Phone_no
C)
...
O)
P)
The abbreviated menu above contains some example data. Selecting the first item brings up the
following menu.
Data-Link DL100 - Data Alarm Field Definition
Data Field: A
A) Start Position [6]
B) Field Length [4]
C) Field Name [Err_no]
…
Field Definition
: Start Position
is the position number of the character to begin a particular
alarm field starting from position 1.
…
Field Definition
: Field Length
is the length of this particular alarm field.
…
Field Definition
: Field Name
is the name given to each alarm field. This name must be
unique, and it must not contain any spaces. It can contain alphanumeric characters and the
underscore, but it must start with a letter. These field names are case sensitive.
Data Alarm Settings: Display Alarm Status
simply outputs a brief account of all of the data
alarm monitors. Following is an example of this status screen:
DL100 Data Alarm Status
Alarm Name Threshold Matches Formula
== ================ ========= ========= ===================================
01 Link Down 3 0 errno="DN1"
Press any key to continue