Manual Rev. 1.02
Page 15
Chapter 3
Getting Connected
3.1 - Power Up Sequence
On startup, the DL100 goes through a boot up process and exhibits the following functionality:
•
Internal buzzer beeps once
•
The power LED flashes once each second for about 15 seconds
•
Modem Active LED lights for 5 seconds if a modem is installed
•
Ethernet Active LED lights for 5 seconds if an Ethernet interface is installed
•
Internal buzzer beeps twice
•
Power LED will begin to blink once every 10 seconds as a ‘heartbeat’ for the DL100
3.2 - Methods of Connecting
Connecting Via Serial Port
Connect to I/O 2 with the 6’ Female DB9 to Female DB9 null modem cable. Ensure that
Dipswitches B7 and B8 are off in order to enable command mode. By default, serial port
command processor access is not password protected. Once connected, the command line is
available in system administrator mode. The following table contains the default passwords for
the DL100.
Mode
Password
User 1
SMDR
User 2
USER2
User 3
USER3
User 4
USER4
I/O 1 Real-Time Socket
ACCESS1
I/O 2 Real-Time Socket
ACCESS2
I/O 3 Real-Time Socket
ACCESS3
I/O 4 Real-Time Socket
ACCESS4
Alarms file Real-Time Socket
ACCESSA
System administrator
SUPER
Figure 8:
Default Passwords