background image

GENERAL INSTRUCTIONS

The system and installation must comply with all state and local laws
regarding the installation of water treatment devices.
“Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.” Systems certified for cyst reduction may be used on disin-
fected waters that may contain filterable cysts.

PERFORMANCE DATA

Flow Rate: . . . . . . . . . . . . . . . . . . . . . . . . . . . .  0.5 GPM (1.9 LPM)
Min./Max. Operating Pressure . . . . . . 25 psi/125 psi (172 - 862 kPa)
Min./Max. Operating Temperature . . . . . . . . 35°F/100°F (2°C/38°C)

INSTALLATION INSTRUCTIONS

NOTICES

Install this filter system on cold water lines only. Do not use on
water lines exceeding 100° F (38°C). Water pressure minimum is
25 psi (172 kPa) and the maximum is 125 psi (862 kPa).

Protect the unit from direct sunlight and freezing temperatures.

Do not use pipe dope or similar compounds. They can ruin plas-
tic pipe. Use teflon tape to seal pipe thread joints.

Keep the unit clean with soap and water. Do not use spray clean-
ers or insecticides near the unit.

Intended for indoor, non-commercial use only.

For extended periods of non-use turn the water off and remove
the filter cartridge. Place the cartridge in a plastic bag, seal, and
refrigerate.

Safety glasses must be worn during installation.

The tubing and hose dimensions are based on outside diameters
(OD). For water line sizes other than those listed, consult a
plumber or hardware store.

Before using the water, flush the new filter for 30 minutes.

Run drinking or cooking water for 10 seconds prior to collecting
the water for use.

Change the filter cartridge if changes in taste, color or flow of
water occur.

This filter is not a water purifier and is not intended for use with
contaminated water.

Comply with all state and local laws regarding the installation of
water treatment devices.

Use only Omnifilter replacement cartridges with this housing, or
the warranty is void.

When to change the filter cartridge

The cartridge should be changed as indicated in the “Performance
Data” section above or sooner if the water pressure at the faucet
begins to drop noticeably or if the cartridge fails to perform 
satisfactorily.

Choose a Location; See Figure 1.

1. Position the filter housing bracket on the wall of the cabinet

nearest the cold water line beneath the sink. Leave a 3” mini-
mum clearance between the bottom of the filter housing and
the floor of the cabinet. Mark the bracket slots on the wall.

2. Drill a 1/8” hole at each of the two marks, and insert the mount-

ing screws. Leave each screw head 1/4” out from the wall. 

Install the Omni faucet; See Figure 2.

3. A. For stainless steel sinks you can drill a 7/8” diameter hole in a

convenient location or use the existing sprayer hole. Mark the
hole location with a punch before drilling.

®

293 Wright Street • Delavan, WI 53115
1-800-937-6664 • www.omnifilter.com

Undersink Water

Filter System

INSTALLATION INSTRUCTIONS

Model OT32 Series A

Threaded Stem
of Faucet

Large Rubber
Washer

Existing Sink
Faucet Sprayer Hole

Large Metal
Washer

Thumb Nut

Figure 2

©2002, Omnifilter

Printed in U.S.A.

OM692 (Rev. 12/5/02)

3"

Cold W

ater Line

1/4"

Figure 1

Replacement Capacity

Cartridges

Gallons/Liters or Months

CB3 Series A

550/2,082 or 4 months

RS2

550/2,082 or 4 months

Summary of Contents for OT32 Series A

Page 1: ...conds prior to collecting the water for use Change the filter cartridge if changes in taste color or flow of water occur This filter is not a water purifier and is not intended for use with contaminat...

Page 2: ...its own hole in cop per tubing but not in iron or brass For brass or iron pipe drill a 5 32 hole in the pipe before mounting the saddle valve Risk of electric shock If possible use a hand or cordless...

Page 3: ...illustrat ed in Figure 9 15 Connect the other piece of plastic tubing from the faucet stem to the OUT port of the filter housing Turn on the Water 16 Open the filter faucet and then slowly open the c...

Page 4: ...mpression Fittings 2 11156 4 Head Assembly 1 13110 5 Tank O Ring 2 19125 6 Filter Cartridge 2 CB3 RS2 7 Sump Tank 2 13210 8 OMNI Filter Wrench 1 13500 9 1 4 Brass Insert 3 12320 10 1 4 Compression Sle...

Page 5: ...dant 30 minutes Avant d utiliser de l eau pour la boisson ou pour la cuisson la laisser couler pendant 10 secondes Remplacer la cartouche d s que l on remarque un changement du go t de l odeur ou du d...

Page 6: ...ousses lectriques Dans la mesure du possible utiliser une perceuse main ou une perceuse sans fil pour percer le tuyau d eau Si l on utilise une perceuse lectrique munie d un cordon s as surer que la p...

Page 7: ...ans l orifice rep r sortie OUT de la cuve du filtre Ouverture de l eau 16 Ouvrir le robinet du filtre puis lentement le robinet de la conduite d eau froide 17 Pour chasser l air du filtre laisser l ea...

Page 8: ...filtre 1 13110 5 Joint torique de la cuve 2 19125 6 Cartouche filtrante 2 CB3 RS2 7 Cuve 2 13210 8 Cl de filtre OMNI 1 13500 9 Embout en laiton de 1 4 de po 3 12320 10 Manchon compression de 1 4 de p...

Page 9: ...por 30 minutos Deje correr el agua potable para beber o cocinar unos 10 segundos antes de recogerla para su uso Cambie el cartucho si observa cambios en el sabor el color o en el caudal del agua Este...

Page 10: ...s posible use un taladro manual o inal mbrico cuando perfore tuber as de agua Si usa un taladro el ctrico aseg rese de que tanto el taladro como el cord n y el toma corriente est n todos debidamente c...

Page 11: ...a parte del tubo de pl stico desde el ca o del grifo a la abertura de salida de la caja del filtro Abra la llave de suministro de agua 16 Abra el grifo del filtro y luego lentamente abra la v lvula de...

Page 12: ...nidad de cabezal 1 13110 5 Aro t rico del tanque 2 19125 6 Cartucho del filtro 2 CB3 RS2 7 Tanque de dep sito 2 13210 8 Llave de tuercas del filtro OMNI 1 13500 9 Inserci n de lat n de 1 4 3 12320 10...