Calibration of the fuel tank is the fuel tank refueling up – from empty to full, following a
certain refueling step, and recording the Omnicomm LLS sensor's readings in the
calibration table. It is recommended to carry out at least 20 steps. It is possible to calibrate
the tank by draining it.
A container may be calibrated by draining.
Calibration of a container with several Omnicomm LLS 5 sensors will be similar to to the
calibration with one sensor. Before the calibration process, add the necessary quantity of
sensors and specify the network addresses. All sensors are calibrated at one time.
Connect several sensors to PC using a KTZ splitter.
Calibration of the tank with one Omnicomm LLS 5 sensor:
1. Empty the fuel tank
2. Connect the sensor to PC according to the diagram in the
section
3. Run Omnicomm Configurator. Select “Calibration”.
Omnicomm Configurator (PC):
If the sensor reading column is not displayed, press the “Add sensor” button. Select the
type of sensor. Specify the network address set in the sensor during setting.
23
Calibration