Minimum output signal frequency, Hz
30…1900
Maximum load current at the frequency output in the
“open collector” mode, mA
300
Resistance of the internal “pull-up resistor” to positive
voltage supply, Ohm
1500
General information:
Measurement range, mm
0…700, 1000, 1500
Basic reduced error of level measurement, %
±1
Ambient temperature, °С
From -40 to +80
Limit temperature, °С
-60 and +85
Relative humidity at 25 °С (without moisture conden-
sation), %
From 5 to 95
Atmospheric pressure, kPa
From 84 to 107
Maximum relative humidity at 25 °С (without moisture
condensation), %
100
Ingress protection rating
IP69k
Operating mode
Continuous
Internal filter size
From 0 to 30
Parameters
Value
Specifications
Omnicomm LLS-AF 4 Fuel Level Sensor