recommended minimum number of control points is 20
10. Press the “Finish calibration” button
11. Save the calibration table in the calibration file (.ctb), Omnicomm Online (.xml) file,
in the Terminal or Indicator, by pressing the “Export” button
When performing the calibration table export to the Omnicomm Online (.xml) file, the
“Ex-port” window will open. Specify the Omnicomm LLS sensor number to display in
Omnicomm Online
The calibration of a container with multiple LLS-AF sensors is performed separately
for each sensor. To import a vehicle profile with multiple LLS-AF calibration tables into
Omnicomm Online:
1. Perform the calibration process for each LLS-AF sensor
2. Export the calibration tables into an Omnicomm Online file (.xml) separately for
each sensor. During the export, specify different numbers for each LLS-AF 4,
starting from 1. Possible options: from 1 up to 4
3. Import the calibration tables into the terminal. In the terminal settings section
“Fuel level sensors”, set the required number of sensors and select the “LLS-AF”
sensor type
4. Export the vehicle profile from the terminal
5. Import the vehicle profile into Omnicomm Online
Sealing
For Omnicomm LLS sensors, the bolt or the self-tapping screw and the connection
may be sealed as shown below:
1. Install the bolt or the self-tapping screw through a hole in the seal
2. Close the seal cover with a snap
Sealing