Omnicomm LLS-AF 4 Fuel

Level Sensor

User Manual
Omnicomm Configurator 6
18.12.2018

Summary of Contents for LLS-AF 4

Page 1: ...Omnicomm LLS AF 4 Fuel Level Sensor User Manual Omnicomm Configurator 6 18 12 2018...

Page 2: ...6 Fuel Tank Preparation 6 Sensor Preparation 8 Setting 8 Empty Full Calibration 9 Omnicomm LLS AF 4 Sensor Setting 10 Installation and Connection 11 Calibration 12 Sealing 14 Appendix List of Equipme...

Page 3: ...iquids that are not the factory grade carbon fuels or contain BIOFUEL METHANOL ETHANOL UREA and similar aggressive components in pure form or as additives for factory grade carbon fuels for use in INT...

Page 4: ...Maximum output voltage V 5 20 Minimum output voltage V 0 15 Digital to analog conversion resolution bit 12 Load resistance on analog output Ohm Not less than 2000 Output signal pulsation Not more than...

Page 5: ...1000 1500 Basic reduced error of level measurement 1 Ambient temperature From 40 to 80 Limit temperature 60 and 85 Relative humidity at 25 without moisture conden sation From 5 to 95 Atmospheric press...

Page 6: ...account the following requirements The installation location should be as close to the geometric center as possible and be placed at the deepest level of the tank When installed the sensor should not...

Page 7: ...mounting holes according to the diagram The mounting hole diameter depends on the material of the tank 4 mm for metal tanks with wall thickness over 3 mm cut M5 thread 7 mm for plastic and metal tank...

Page 8: ...2 Use oil and petrol resistant non conductive sealant to fill the insulation cap included in the kit to 1 4 1 5 of its volume Recommended sealants PERMATEX MotoSeal Black ABRO Black ABRO Red 3 Put the...

Page 9: ...r in the fuel to the full length of the measuring probe 3 Wait for the green indicator Stable to appear Press the button Full to record the value corresponding to a full tank 4 Remove the sensor from...

Page 10: ...th account for severe operating conditions Type of signal select Analog or Frequency For the analog signal Max voltage value 5 20 V set the maximum voltage value Default value 5 V Min voltage value 0...

Page 11: ...th bolts first put a seal one on each bolt a spacer and a spring washer when securing onto a plastic tank with wall thickness of more than 3 mm use the self tapping screws and a seal one on each self...

Page 12: ...on of the fuel tank is performed by filling up the tank from empty to full with a certain filling interval and recording the Omnicomm LLS sensor readings in the calibration table A container may be ca...

Page 13: ...esolution to enhance precision 5 Press the Start continue calibration button 6 Fill with an amount of fuel equal to the flow interval Filling should be performed with a measuring vessel or under liqui...

Page 14: ...1 Perform the calibration process for each LLS AF sensor 2 Export the calibration tables into an Omnicomm Online file xml separately for each sensor During the export specify different numbers for eac...

Page 15: ...S AF 4 connector to the mounting cable until it clicks 2 Run the flexible part of the seal through the connectors 3 Run the flexible part of the seal through the hole in the seal body 4 Tighten up the...

Page 16: ...Tap M5 with holder 1 7 Snap seal for bolt self tapping screw 1 8 Personal computer 1 9 Omnicomm Configurator program 1 10 Omnicomm UNU USB or UNU setting device 1 11 DC power supply unit 10 15 V 0 5...

Page 17: ...15 Seal tie for Molex connector 1 Name Quantity Appendix List of Equipment for OmnicommLLS AF 4 Fuel Level Sensors Installation OmnicommLLS AF 4 Fuel Level Sensor 17...

Page 18: ...info omnicomm world com www omnicomm world com...