background image

Patent No. US 8,856,780 CA 2759622

MODULE CONNECTORS

M9 (CODE ALARM RF) - 4 PIN RED

  M11 (TELEMATIC) - 4 PIN BLUE

PROGRAMMING BUTTON

M7 (PRESTIGE/PURSUIT RF) - 6 PIN BLACK

LED 1 (BYPASS)

LED 2 (RS)

  M10 (RF PORT/WEBLINK) - 4 PIN BLACK

M12 (NC) - 4 PIN YELLOW

M13 (ALARM SENSOR) - 4 PIN WHITE

M8 (CODE ALARM RF) - 5 PIN BLACK

MODULE

7
9

3

10

8

6

4

1

2

5

7

9

3

10

8

11

13

14

12

15

17

18

19

20

16

6

4

1

2

5

4

5

3

2

1

6

M5

M4

01 GREEN•BLACK DOT - LOCK (-) OUTPUT

01 GREEN•BLACK DOT - LOCK (-) OUTPUT

02 BLUE•BLACK DOT - UNLOCK (-) OUTPUT

02 BLUE•BLACK DOT - UNLOCK (-) OUTPUT

03 RED/WHITE•BLACK DOT - TRUNK RELEASE (-) OUTPUT

03 RED/WHITE•BLACK DOT - TRUNK RELEASE (-) OUTPUT

04 GREEN/WHITE•BLACK DOT - ARM (-) OUTPUT

04 GREEN/WHITE•BLACK DOT - ARM (-) OUTPUT

05 GREEN/BLACK•BLACK DOT - DISARM (-) OUTPUT

05 GREEN/BLACK•BLACK DOT - DISARM (-) OUTPUT

06 BLUE/WHITE•BLACK DOT - GWR (-) OUTPUT

06 BLUE/WHITE•BLACK DOT - GWR (-) OUTPUT

07 BROWN•BLACK DOT - SIREN (+) OUTPUT

07 BROWN•BLACK DOT - SIREN (+) OUTPUT

08 WHITE/PURPLE•BLACK DOT - POC 1 - 2ND UNLOCK OTHER DOORS (-) OUTPUT

08 WHITE/PURPLE•BLACK DOT - POC 1 - 2ND UNLOCK OTHER DOORS (-) OUTPUT

09 PURPLE/BLACK•BLACK DOT - POC 2 - RAP SHUTDOWN (-) OUTPUT

09 PURPLE/BLACK•BLACK DOT - POC 2 - RAP SHUTDOWN (-) OUTPUT

10 WHITE/BLACK•BLACK DOT - POC 3 - HORN (-) OUTPUT

10 WHITE/BLACK•BLACK DOT - POC 3 - HORN (-) OUTPUT

11 BROWN/BLACK•BLACK DOT - POC 4 - STARTER KILL (-) OUTPUT

11 BROWN/BLACK•BLACK DOT - POC 4 - STARTER KILL (-) OUTPUT

12 WHITE•BLACK DOT - PARKING LIGHTS (-) OUTPUT

01 BROWN•SILVER DOT - BRAKE (+) INPUT

02 BLACK/WHITE•SILVER DOT - E-BRAKE (-) INPUT

03 PURPLE•SILVER DOT - DOOR (+) INPUT

04 GREEN•SILVER DOT - DOOR (-) INPUT

05 PURPLE/WHITE•SILVER DOT - TACH (-) INPUT

06 WHITE/BLUE•SILVER DOT - X-TRIGGER (-) INPUT

07 GRAY•SILVER DOT - HOOD (-) INPUT

08 BLUE•SILVER DOT - TRUNK (-) INPUT

09 GRAY/BLACK•SILVER DOT - GLOW PLUG (+) INPUT

10 TAN•SILVER DOT - EXT ALARM SENSOR (-) INPUT

FUNCTIONS DEFINED BY FIRMWARE

FUNCTIONS DEFINED BY FIRMWARE

M3

M2

4

5

3

2

1

6

M6

FUNCTIONS DEFINED BY FIRMWARE

M3 - 10 PIN WHITE

M2 - 12 PIN BLACK

M5 - 6 PIN BLUE

M4 - 20 PIN BLACK

M1 - 8 PIN BLACK

M6 - 6 PIN BLACK

AUTOMATIC

TRANSMISSION

CUT LOOP

4

2

8

1
3
5
7

6

M5

M6

M4

M3

M2

M1

7

9

3

10

8

11

12

6

4

1

2

5

M1

01 ORANGE - ACCESSORY (+)

01 ORANGE - ACCESSORY (+)

02 RED - POWER (30A)

02 RED - POWER (30A)

03 PURPLE - STARTER (+)

03 PURPLE - STARTER (+)

04 PINK/WHITE - PROG. RELAY #4 - IGNITION 2  (+) (DEFAULT)

04 PINK/WHITE - PROG. RELAY #4 - IGNITION 2  (+) (DEFAULT)

05 PINK - IGNITION (+)

05 PINK - IGNITION (+)

07 RED - POWER (30A)

07 RED - POWER (30A)

08 BLACK - GROUND

08 BLACK - GROUND

06 WHITE - PROG. RELAY #5 (10A) - PARKING LIGHTS (+) (DEFAULT)

06 WHITE - PROG. RELAY #5 (10A) - PARKING LIGHTS (+) (DEFAULT)

CONNECTOR PINOUT

MODULE LAYOUT - 1 OF 1

www.idatalink.com

Automotive Data Solutions Inc. © 2022

OL-RS-BA

PAGE 4 OF 28

• 20220110

Summary of Contents for OL-RS-BA

Page 1: ...tes available in Weblink ADS is not responsible for any damages whatsoever including but not limited to any consequential damages incidental damages damages for loss of time loss of earnings loss of profit commercial loss loss of economic opportunity and the like that may or may not have resulted from the use misuse improper installation or operation of its products ADS reserves itself the right t...

Page 2: ...ories 17 18 Remote Programming Procedure 19 Valet Mode Programming Procedure 20 OL RS BA EXCALIBUR Compatible Accessories 21 22 Remote Programming Procedure 23 Valet Mode Programming Procedure 24 WELCOME Congratulations on the purchase of your OL RS BA solution You are now a few simple steps away from enjoying your new remote starter unit with enhanced features Before starting your installation pl...

Page 3: ...BA OMEGALINK Compatible Accessories 25 26 Remote Programming Procedure 27 Valet Mode Programming Procedure 28 NEED HELP 1 800 921 TECH support caralarm com info caralarm com www facebook com OmegaRD www idatalink com Automotive Data Solutions Inc 2022 OL RS BA PAGE 3 OF 28 20220110 ...

Page 4: ...WHITE BLACK BLACK DOT POC 3 HORN OUTPUT 11 BROWN BLACK BLACK DOT POC 4 STARTER KILL OUTPUT 11 BROWN BLACK BLACK DOT POC 4 STARTER KILL OUTPUT 12 WHITE BLACK DOT PARKING LIGHTS OUTPUT 01 BROWN SILVER DOT BRAKE INPUT 02 BLACK WHITE SILVER DOT E BRAKE INPUT 03 PURPLE SILVER DOT DOOR INPUT 04 GREEN SILVER DOT DOOR INPUT 05 PURPLE WHITE SILVER DOT TACH INPUT 06 WHITE BLUE SILVER DOT X TRIGGER INPUT 07 ...

Page 5: ...rake pedal Press and release the module s programming button OR if the remotes are already programmed to the vehicle press and hold the start button of the remote for 2 5 seconds Wait LED 2 will flash GREEN See the Module Diagnostics page Release the brake pedal Module Programming Procedure completed www idatalink com Automotive Data Solutions Inc 2022 OL RS BA PAGE 5 OF 28 20220110 ...

Page 6: ...atic transmission Reset and re learn 9 ORANGE flashes Loop not cut Ensure loop is cut for automatic transmission Reset and re learn 10 ORANGE flashes Boot loader update failed Contact technical support 11 ORANGE flashes T harness detection does not match install type selection in Weblink TACH PROGRAMMING Solid RED Tach learn in progress 1 GREEN flash Tach signal programmed in analog 2 GREEN flashes Tac...

Page 7: ...itiated Waiting to complete takeover after brake press TRANSMITTER PROGRAMMING Solid RED Remote programming in progress waiting for remote pairing 1 GREEN flash Remote programmed 4 RED flashes Shutdown remote starter before attempting remote programming 5 RED flashes Engine must be off before attempting remote programming 6 RED flashes System must be unlocked disarmed before attempting remote programm...

Page 8: ...heat protection REMOTE STARTER SHUTDOWN ERROR CODES NOTES PARKING LIGHT FLASHES DIAGNOSTIC I WARNING The following applies only when the parking lights are connected and supported by the system 4 1 Engine tach signal was lost 4 2 Emergency brake signal was lost 4 3 Foot brake ON detected II If the engine shuts down after a remote starter sequence use the query command from a compatible aftermarket...

Page 9: ... II If the alarm has been triggered the parking lights will flash five 5x times followed by the alarm activation event 5 4 4 Hood open 5 5 5 Zone 2 input triggered 5 6 6 Foot brake ON III The alarm event code is also displayed in a repeating pattern on the antenna s LED when the alarm is triggered until unlock is received 5 7 7 Ignition ON 5 8 8 Motion detected 5 9 9 Tilt detected 5 10 10 Warn awa...

Page 10: ...ect the M1 BLACK 8 pin connector and the M4 BLACK 20 pin connector PRESS AND HOLD the module s programming button while connecting the M1 BLACK 8 pin connector and the M4 BLACK 20 pin connector Wait LED 1 will flash RED RELEASE programming button LED 1 will turn RED for 2 seconds Module RESET completed Reconnect all connectors Repeat programming procedure Failure to follow procedure may result with...

Page 11: ...nnections Repeat the test and call technical support if the problem persists 8 Press the START STOP button once 1x on the aftermarket keyfob to remote start vehicle Question 6 Does the vehicle remote start YES Go to next step NO Verify the remote programming the RF connections and check the remote start error codes Repeat the test and call technical support if the problem persists 9 Press the STAR...

Page 12: ...tep NO Verify the RAP SHUTDOWN connections as illustrated in the wiring diagram Repeat the test and call technical support if the problem persists 6 Open hood 7 If not already installed affix the mandatory orange warning sticker under the hood and proceed to next step 8 Press LOCK button three times 3x rapidly on the OEM keyfob to remote start vehicle Question 4 Does the vehicle remote start YES T...

Page 13: ...nsor Magnetic and Glass Breaking Sensor Dual Zone Digital Tilt Switch Dual Zone Proximity Sensor AU 84TM Dual Alarm Stage Shock Sensor AU 84TN Dual Zone Magnet Shock Sensor AU 85TN Magnetic and Glass Breaking Sensor AU 46TD Dual Zone Digital Tilt Switch AU 94TM Dual Zone Proximity Sensor Dual Zone Shock Sensor AU 84TDPB Dual Zone Shock Sensor OMEGALINK AU 84TDPB AU 84TM AU 84TN AU 85TN AU 46TD AU ...

Page 14: ...STOPPER COMPATIBLE ACCESSORIES 2 OF 2 ANTENNA MODULE M10 CRIMESTOPPER RF KIT SOLD SEPARATELY NC MODULE M11 LINKR TELEMATIC KIT SOLD SEPARATELY www idatalink com Automotive Data Solutions Inc 2022 OL RS BA PAGE 14 OF 28 20220110 OL RS BA CRIMESTOPPER ...

Page 15: ... remote starter LED will turn RED and the antenna LED will flash Press once 1x on LOCK button of aftermarket remote The remote starter LED will flash GREEN once 1x then will turn RED To program additional remotes repeat steps 5 to 6 using each additional remote Set ignition to OFF position The remote starter LED will turn OFF and the antenna LED will turn OFF The parking lights will flash twice 2x th...

Page 16: ...r is not functional Keyless entry Lock and Unlock will remain functional Time restriction Complete next step within 7 seconds Cycle ignition ON twice 2x OFF ON rapidly Press and release the BRAKE pedal three times 3x Parking Light will flash once 1x then will flash twice 2x Set ignition to OFF position Valet Mode completed To exit valet mode repeat steps 2 to 6 www idatalink com Automotive Data Solu...

Page 17: ...nsor Magnetic and Glass Breaking Sensor Dual Zone Digital Tilt Switch Dual Zone Proximity Sensor AU 84TM Dual Alarm Stage Shock Sensor AU 84TN Dual Zone Magnet Shock Sensor AU 85TN Magnetic and Glass Breaking Sensor AU 46TD Dual Zone Digital Tilt Switch AU 94TM Dual Zone Proximity Sensor Dual Zone Shock Sensor AU 84TDPB Dual Zone Shock Sensor OMEGALINK AU 84TDPB AU 84TM AU 84TN AU 85TN AU 46TD AU ...

Page 18: ...ULE M10 DIRECTED XL202 OMEGALINK ADSHRNRSXL02 RF KIT SOLD SEPARATELY NC NC NC NC NC NC DIRECTED SMARTSTART OMEGALINK ADSHRNSM01 TELEMATIC KIT SOLD SEPARATELY MODULE M11 BLACK 4 PIN WHITE 4 PIN DIRECTED SMARTSTART ADS HRN RS SM01 www idatalink com Automotive Data Solutions Inc 2022 OL RS BA PAGE 18 OF 28 20220110 OL RS BA DIRECTED ...

Page 19: ...1 AFTERMARKET REMOTE PROGRAMMING NOTES I All aftermarket remotes must be programmed to the RF Kit Refer to the RF Kit user guide for aftermarket remote features and programming procedures www idatalink com Automotive Data Solutions Inc 2022 OL RS BA PAGE 19 OF 28 20220110 OL RS BA DIRECTED ...

Page 20: ...r is not functional Keyless entry Lock and Unlock will remain functional Time restriction Complete next step within 7 seconds Cycle ignition ON twice 2x OFF ON rapidly Press and release the BRAKE pedal three times 3x Parking Light will flash once 1x then will flash twice 2x Set ignition to OFF position Valet Mode completed To exit valet mode repeat steps 2 to 6 www idatalink com Automotive Data Solu...

Page 21: ...nsor Magnetic and Glass Breaking Sensor Dual Zone Digital Tilt Switch Dual Zone Proximity Sensor AU 84TM Dual Alarm Stage Shock Sensor AU 84TN Dual Zone Magnet Shock Sensor AU 85TN Magnetic and Glass Breaking Sensor AU 46TD Dual Zone Digital Tilt Switch AU 94TM Dual Zone Proximity Sensor Dual Zone Shock Sensor AU 84TDPB Dual Zone Shock Sensor OMEGALINK AU 84TDPB AU 84TM AU 84TN AU 85TN AU 46TD AU ...

Page 22: ...2 OF 2 ANTENNA NC MODULE M10 EXCALIBUR RF 10 EDP RF 30 EDP RF 50 EDP ULTIMATE 10 EDP ULTIMATE 30 EDP RF KIT SOLD SEPARATELY NC MODULE M11 LINKR TELEMATIC KIT SOLD SEPARATELY www idatalink com Automotive Data Solutions Inc 2022 OL RS BA PAGE 22 OF 28 20220110 OL RS BA EXCALIBUR ...

Page 23: ...1 AFTERMARKET REMOTE PROGRAMMING NOTES I All aftermarket remotes must be programmed to the RF Kit Refer to the RF Kit user guide for aftermarket remote features and programming procedures www idatalink com Automotive Data Solutions Inc 2022 OL RS BA PAGE 23 OF 28 20220110 OL RS BA EXCALIBUR ...

Page 24: ...r is not functional Keyless entry Lock and Unlock will remain functional Time restriction Complete next step within 7 seconds Cycle ignition ON twice 2x OFF ON rapidly Press and release the BRAKE pedal three times 3x Parking Light will flash once 1x then will flash twice 2x Set ignition to OFF position Valet Mode completed To exit valet mode repeat steps 2 to 6 www idatalink com Automotive Data Solu...

Page 25: ...nsor Magnetic and Glass Breaking Sensor Dual Zone Digital Tilt Switch Dual Zone Proximity Sensor AU 84TM Dual Alarm Stage Shock Sensor AU 84TN Dual Zone Magnet Shock Sensor AU 85TN Magnetic and Glass Breaking Sensor AU 46TD Dual Zone Digital Tilt Switch AU 94TM Dual Zone Proximity Sensor Dual Zone Shock Sensor AU 84TDPB Dual Zone Shock Sensor OMEGALINK AU 84TDPB AU 84TM AU 84TN AU 85TN AU 46TD AU ...

Page 26: ...OMEGALINK COMPATIBLE ACCESSORIES 2 OF 2 ANTENNA MODULE M10 OMEGALINK RF KIT SOLD SEPARATELY NC MODULE M11 LINKR TELEMATIC KIT SOLD SEPARATELY www idatalink com Automotive Data Solutions Inc 2022 OL RS BA PAGE 26 OF 28 20220110 OL RS BA OMEGALINK ...

Page 27: ... remote starter LED will turn RED and the antenna LED will flash Press once 1x on LOCK button of aftermarket remote The remote starter LED will flash GREEN once 1x then will turn RED To program additional remotes repeat steps 5 to 6 using each additional remote Set ignition to OFF position The remote starter LED will turn OFF and the antenna LED will turn OFF The parking lights will flash twice 2x th...

Page 28: ...r is not functional Keyless entry Lock and Unlock will remain functional Time restriction Complete next step within 7 seconds Cycle ignition ON twice 2x OFF ON rapidly Press and release the BRAKE pedal three times 3x Parking Light will flash once 1x then will flash twice 2x Set ignition to OFF position Valet Mode completed To exit valet mode repeat steps 2 to 6 www idatalink com Automotive Data Solu...

Reviews: