background image

Page 4

Concealed Transmitter Codes: Each system includes two transmitters, and up to two  additional

transmitters can be stored in the unit's memory for your convenience. Each transmitter has its own
unique code. Thus, no other transmitter is coded the same as yours. In fact, no one, including the
factory, can program another transmitter exactly like yours because the code is built inside the
transmitter's microprocessor and cannot be seen or copied.

Transmitter Code Jumping

TM

: Each time you press a transmitter button its signal will advance

to the next digital code in sequence. Each time the keyless entry module receives the correct digitally
encoded signal from your transmitter, the receiver will then advance to the next digital code in
sequence to match the transmitter. Therefore, you can never transmit the same code twice, thereby
preventing a code grabbing device from operating your system.

Transmitter Battery Saver Feature: Many times transmitter batteries are prematurely exhausted

because the transmitter buttons are inadvertently pressed by objects while in a pocket or purse. The
transmitter will turn itself "off" after a short period of continuous transmission, and thus prevent
drained transmitter batteries.

Transmitter Features

 The REC-11 includes a Red LED Status Light to inform you of the system's operational

condition.   Your system features a Starter Disable circuit, the status of which is also reflected by the
Red LED Status Light.  These are the conditions of the LED Status Light:

L E D Status Light

Page 17

11)

The Starter Disable Will Automatically Engage 90 Seconds After The Ignition Switch

Is Turned "Off": Default OFF.
When this Feature is activated, the Starter Disable circuit will automatically engage 90
seconds after the ignition switch is turned "off".  Turning "on" the ignition switch during this
90 second period will reset timer period.  Once the Starter Disable circuit engages, the
transmitter's use to unlock the doors or putting the system into Valet Mode are required to
disengage it.

12)

The Starter Disable Will Automatically Engage 90 Seconds After The Transmitter

      Is Used To Unlock The Doors: Default OFF (press LOCK).

When this Feature is activated, the Starter Disable circuit will automatically reengage 90
seconds after remotely unlocking the doors.  Turning "on" the ignition switch during this
90 second period will override this Feature, preventing the automatic engagement.

13)

Ignition Activated Anti-Carjacking: Default OFF.

This Feature adds automatic Anti-Carjacking protection; Automatic Anti-Carjacking protec-
tion is activated every time the ignition switch is turned "on".  In this form of Anti-Carjacking,
the Valet Switch may be pressed within 60 seconds of turning the ignition "on", including the
final 7 seconds when the piezo is beeping to remind you of impending engagement of the
feature.  At 60 seconds the piezo starts making a siren sound. At 90 seconds the starter interrupt
output will activate. Once the siren sound occurs, Anti-Carjacking cannot be canceled unless
the ignition is turned "off", then back "on"; the Valet Switch must be pressed once within 10
seconds of turning the ignition back "on". This is the only way to cancel or turn off the Anti-
Carjacking Feature - once activated, the transmitter cannot be used to cancel or turn off the
Feature.

Summary of Contents for + REC-11

Page 1: ...r Omega Research and Development Inc s labor and return shipping to the original owner during the lifetime of the car in which it was originally installed All products for warranty repair must be sent...

Page 2: ...ns as enhanced by the factory set Programmable Features Asyoubecomemorefamiliarwiththebasicoperationsthatthismodelperforms thisManual will further discuss the User Programmable Features and then expla...

Page 3: ...onds The piezo will start beeping 53 seconds later and for the next seven seconds pressing the Valet Switch once will cancel the Anti Carjacking Feature At 60 seconds the piezo starts making a siren s...

Page 4: ...Disable Will Automatically Engage 90 Seconds After The Ignition Switch Is Turned Off Default OFF When this Feature is activated the Starter Disable circuit will automatically engage 90 seconds after...

Page 5: ...omatic relocking 4 Doors Lock With Ignition On Default ON 5 Ignition Off Unlock 1 Default ON 6 Ignition Off Unlock 2 Default ON These three Features control the doorlocks in relation to the ignition b...

Page 6: ...y beeping twice If 10 seconds of no programming activity expires not pressing theLOCKorUNLOCKbuttonsorselectinganotherFeature thesystemwillexittheFeatures Programming Mode which is indicated by soundi...

Page 7: ...rate but the Starter Disable will not operate and any programmed automatic functions are suspended Overriding The System As mentioned in the previous section once the Starter Disable is engaged theign...

Page 8: ...e automatically 90 seconds after the ignition switch is turned off These automatic Starter Disable options are explained in more detail in the User Programmable Features section of this Owner s Manual...

Page 9: ...er commands If desired the audible confirmation may be deactivated Automatic Starter Interrupt Engagement If desired the starter interrupt circuit may be programmed to automatically engage 90 seconds...

Page 10: ...he last Dealer Programmable Options Page 11 Activating The Trunk Release Also Unlocks The Doors This system allows you to make the choice of whether the convenience of using your transmitter to gain t...

Reviews: