LED Off ...................................................................... Ignition switch is "On" OR the system

                                                                             is "at rest", indicating that no automatic
                                                                                 features will occur.

LED On Solid Red ..................................................... System is in "Valet Mode".

LED Flashing Rapidly ................................................ An automatic function countdown is in

                                                                                progress.

LED Flashing Slowly ................................................. Starter Disable is engaged.  This will occur

whenever the transmitter is used to lock the
doors.  The Starter Disable may also be
programmed to operate automatically.

LED Flashes 1 To 4 Times After Ignition "On" ........ Number of transmitters stored in the system.

                                                                              These four indicators are part of the Auto-
                                                                             matic Transmitter Verification

TM

 feature.

The REC-11 includes a  piezo buzzer for audible confirmation when a transmitter command is

received: one beep acknowledges a LOCK command and two beeps acknowledge an UNLOCK
command.  If the system is in Valet Mode, the piezo buzzer will also beep once when the ignition is

Audible  Confirmation

Page 16

transmitter has been used to unlock them.  Turning the ignition "on" during the 90 second
period will cancel the automatic relocking.

4)

Doors Lock With Ignition "On": Default ON.

5)

Ignition "Off" Unlock #1: Default ON.

6)

Ignition "Off" Unlock #2: Default ON.

These three Features control the doorlocks in relation to the ignition being turned on or off.

7)

Operating Trunk Release Also Unlocks Doors: Default ON.

When the transmitter's II button is pressed for 3 seconds to activate the Trunk Release
output, this Feature will unlock the doors.  Both doorlock unlock outputs will operate.

8)

Doorlock Pulse Time .8/3 Seconds: Default .8 Second (press LOCK).

Some vehicle's power doorlocking systems (example: Mercedes Benz pneumatic systems)
require a longer output pulse to operate properly. This Feature allows the installer the
flexibility to accommodate such systems.

9)

Double Unlock Pulse: Default OFF.

This is another Feature provided for the installer's benefit. Some newer vehicles require a
double pulse to remotely unlock the doors and/or to disarm a factory-equipped security
system.

10)

Confirmation Chirps: Default ON.

This Feature causes the system to acknowledge the reception of a transmitter command.
Pressing LOCK produces one beep; pressing UNLOCK produces two beeps.  Turning this
Feature OFF silences the confirmation beeps.

Summary of Contents for + REC-11

Page 1: ...r Omega Research and Development Inc s labor and return shipping to the original owner during the lifetime of the car in which it was originally installed All products for warranty repair must be sent...

Page 2: ...ns as enhanced by the factory set Programmable Features Asyoubecomemorefamiliarwiththebasicoperationsthatthismodelperforms thisManual will further discuss the User Programmable Features and then expla...

Page 3: ...onds The piezo will start beeping 53 seconds later and for the next seven seconds pressing the Valet Switch once will cancel the Anti Carjacking Feature At 60 seconds the piezo starts making a siren s...

Page 4: ...Disable Will Automatically Engage 90 Seconds After The Ignition Switch Is Turned Off Default OFF When this Feature is activated the Starter Disable circuit will automatically engage 90 seconds after...

Page 5: ...omatic relocking 4 Doors Lock With Ignition On Default ON 5 Ignition Off Unlock 1 Default ON 6 Ignition Off Unlock 2 Default ON These three Features control the doorlocks in relation to the ignition b...

Page 6: ...y beeping twice If 10 seconds of no programming activity expires not pressing theLOCKorUNLOCKbuttonsorselectinganotherFeature thesystemwillexittheFeatures Programming Mode which is indicated by soundi...

Page 7: ...rate but the Starter Disable will not operate and any programmed automatic functions are suspended Overriding The System As mentioned in the previous section once the Starter Disable is engaged theign...

Page 8: ...e automatically 90 seconds after the ignition switch is turned off These automatic Starter Disable options are explained in more detail in the User Programmable Features section of this Owner s Manual...

Page 9: ...er commands If desired the audible confirmation may be deactivated Automatic Starter Interrupt Engagement If desired the starter interrupt circuit may be programmed to automatically engage 90 seconds...

Page 10: ...he last Dealer Programmable Options Page 11 Activating The Trunk Release Also Unlocks The Doors This system allows you to make the choice of whether the convenience of using your transmitter to gain t...

Reviews: