background image

You received two remote control transmitters to operate your Remote Keyless Entry System.

The system LED will flash two times every time the ignition key is turned “on”.  This alert will last
90 seconds for the first 48 hours after a new installation.  The alert will shorten to 10 seconds after the
first 48 hours. If a new remote is coded into the system the alert will again be 90 seconds for 48 hours.
This Patented feature alerts you if someone has covertly added an unauthorized transmitter to your
system, and is found only in Omega Research and Development products.

Automatic  Transmitter   Verification

TM

REC-11  Operating  Instructions

Introduction

The REC-11 is a fully-featured Remote Keyless Entry System with Starter Disable designed by

Omega Research and Development, a leader in vehicle security and convenience systems since 1970.
Please note that this advanced personal convenience system has Programmable Features which can
be configured by the installer.  These instructions describe operations of the system with the factory
default settings of the Programmable Features.  Please see your installing dealer for more details on
Programmable Features.

To learn how to operate your system, this Owner's Operation Manual will begin with Transmitter

Functions, then explain the system's other operations as enhanced by the factory-set Programmable
Features. As you become more familiar with the basic operations that this model performs, this Manual
will further discuss the User Programmable Features, and then explain how change them to configure
the system to suit your personal needs.

Page 2

Page 19

17)   One or Two Button Operation: Default Two

This feature allows the unit to be locked and unlocked from two separate buttons or have
the unit “toggle” the lock and unlock operations from one button.

List of Programmable Features:

1) Secret Override Code: Default 1&0 Programming Switch Press

2) Doors Automatically Lock 90 Seconds After The Ignition Is Turned “Off” : Default OFF

3) Doors Automatically Relock 90 Seconds After Remotely Unlocking : Default OFF

4) Doors Lock With Ignition “On” : Default ON

5) Ignition “Off” Unlock #1 : Default ON

6) Ignition “Off” Unlock #2 : Default ON

7) Operating Trunk Release Also Unlocks Doors: Default ON

8) Doorlock Pulse Time .8/3 Seconds :Default .8 Second

9) Double Unlock Pulse : Default OFF

10) Audible Confirmation Of Received Transmitter Signal : Default ON

11) The Starter Disable Will Automatically Engage 90 Seconds After The Ignition Switch

       Is Turned “Off” : Default OFF

12) The Starter Disable Will Automatically Engage 90 Seconds After The Transmitter Is

      Used To Unlock The Doors : Default OFF

13) Ignition Activated Anti-Carjacking : Default OFF

14) Transmitter Activated Anti-Carjacking : Default OFF

15) 30 Second Parking Lights Upon Unlock : Default ON

16) “Panic” / 3rd Channel From Button III : Default 3rd Channel

Summary of Contents for + REC-11

Page 1: ...r Omega Research and Development Inc s labor and return shipping to the original owner during the lifetime of the car in which it was originally installed All products for warranty repair must be sent...

Page 2: ...ns as enhanced by the factory set Programmable Features Asyoubecomemorefamiliarwiththebasicoperationsthatthismodelperforms thisManual will further discuss the User Programmable Features and then expla...

Page 3: ...onds The piezo will start beeping 53 seconds later and for the next seven seconds pressing the Valet Switch once will cancel the Anti Carjacking Feature At 60 seconds the piezo starts making a siren s...

Page 4: ...Disable Will Automatically Engage 90 Seconds After The Ignition Switch Is Turned Off Default OFF When this Feature is activated the Starter Disable circuit will automatically engage 90 seconds after...

Page 5: ...omatic relocking 4 Doors Lock With Ignition On Default ON 5 Ignition Off Unlock 1 Default ON 6 Ignition Off Unlock 2 Default ON These three Features control the doorlocks in relation to the ignition b...

Page 6: ...y beeping twice If 10 seconds of no programming activity expires not pressing theLOCKorUNLOCKbuttonsorselectinganotherFeature thesystemwillexittheFeatures Programming Mode which is indicated by soundi...

Page 7: ...rate but the Starter Disable will not operate and any programmed automatic functions are suspended Overriding The System As mentioned in the previous section once the Starter Disable is engaged theign...

Page 8: ...e automatically 90 seconds after the ignition switch is turned off These automatic Starter Disable options are explained in more detail in the User Programmable Features section of this Owner s Manual...

Page 9: ...er commands If desired the audible confirmation may be deactivated Automatic Starter Interrupt Engagement If desired the starter interrupt circuit may be programmed to automatically engage 90 seconds...

Page 10: ...he last Dealer Programmable Options Page 11 Activating The Trunk Release Also Unlocks The Doors This system allows you to make the choice of whether the convenience of using your transmitter to gain t...

Reviews: