background image

 

2

 

  Table of Contents 
 

 
Specification………….

Page

 2 

 

Package inventory…..

Page

 3 

 

 
Safety talk ……..……..

Page

 3  

 

Operation……………...

Page

 4 

 

Safety Systems……….

Page

 5 

  

Installation…………... 

Page

 5 

   

Operation………………

Page 

 

Recommendations for..Page 8 
 New installation 
 
Temperature increase   
Diagra

m    ………………     Page 

 
 

 
 

 

 
 

 
 

 

 
 

 
 

 

 
 

 
 

 

 
 

 
 

Specification 

                       

 

Natural Gas Input           Minimum 28,000 Btu          

Maximum112.000Btu 

LPG Input                        Minimum 27.000 Btu 

                                       Maximum112.000 Btu  

 

Gas Connection               ½” NPT 

 
Water Connection           3/4  NPT 

Water pipes location      On the top of the  

                                         unit. 

 

Water Pressure              Min                    19 psi 
                                         Max                 150 psi  

                                         Recommended 45 psi  

 

Natural Gas Pressure        

                            Inlet      Min     0.33 psi 

                                          Max     0.43 psi 
 

LP Gas Pressure Inlet      Min     0.43 psi 

                                           Max    0.47 psi 

 

Weight                              37 lbs 

 
Dimensions                     

32.5" X 15.5" X 9.5"

 

 

Electrical power used     115 V /60Hz 

 

Power usage                    60W 

Ignition                            Electronic ignition 

 
Safeties:                           Ion flame detector 

                                          Max temp sensors 

                                          Water leak sensor 

                                          Flame inspection  

                                          window 

                                          Anti freezing device 
     

 

 

     Pressure sensor/device 

                                           

                                           

 

 

 

 

 

 

 

 

 

 

 

 

 
 

Summary of Contents for OME 514-PV

Page 1: ...ormation and instructions in this manual is not followed exactly a fire or explosion is possible causing property damage personal injury or death Warning Any Gas appliance creates flue gasses carbon m...

Page 2: ...27 000 Btu Maximum112 000 Btu Gas Connection NPT Water Connection 3 4 NPT Water pipes location On the top of the unit Water Pressure Min 19 psi Max 150 psi Recommended 45 psi Natural Gas Pressure Inle...

Page 3: ...the actual edition of National Fuel Gas Code ANSI Z223 1 NFPA 54 in USA or Installation Codes for Gas Burning Appliances in Canada the CGA standard CAN CGA B149 1 or CAN CGA B 149 2 2 Check the ratin...

Page 4: ...in domestic water heating When you open the hot water faucet the computer sensors detect the depressurization of the line and command the gas valve and the ignition relay control the commencing of th...

Page 5: ...emperature on any place on the unit is under 100 F so the possibility of Fire by contact is eliminated Freeze Prevention We see no reason to install your water heater outside OME 514 PV is been design...

Page 6: ...ntenance The unit is virtual maintenance free with the exception of the de scaling every 1 to 3 years based of the PH of the local water supply The harder is the water more often the de scaling has to...

Page 7: ...f the unit go over 140F and the unit shuts off The unit will not start before you close the faucet and reopen again Fix Dial back the gas knob to reduce the temperature 1 6 of the dial It can also be...

Page 8: ...00 86 91 96 101 106 111 5 25 84 89 94 99 104 109 The result for Output temperature was reduced to 130 Degrees by the temperature safety devices anti scalding device included in the design of the unit...