background image

                                                                                                         Temperature/Event Adapter

       10

on paper replacement.

This is an error message which indicates that the
printer has not been set to ON LINE. Refer to the
owners manual for specific instructions on
setting the printer controls.

V

IEWING RECORDED DATA

One of the features of the Service Logger is that recorded information may be
directly read on the display. The same filter functions that are available for
printing data are also available for reading data on the display. This allows the
user to let the Service Logger scan the recorded data and display only the
information that is of interest to the user. Without this function the user would
have to manually scan a potential 4000 data samples to find the information of
interest.

Press and hold 

                   

M E N U

               

 

E N T E R

 until this display

appears. The actual recording rate is
unimportant.

Press 

                   

M E N U

               

 

E N T E R

 again to cycle to the next

screen. As before, the scale does not pertain to
the viewing function.

This is where the viewing function is accessed.

Press  

              

S T A T U S

 or 

             

R E C O R D

 to access this

menu.

Press the 

             

R E C O R D

 button once to scroll to this

function.

Press 

                   

M E N U

               

 

E N T E R

 to advance to the next print selection.

This is the first filter option. Selecting this will dis-
play every data sample that has been recorded.

Press  

              

S T A T U S

 to select a temperature filter

PRINTER IS NOT

ON LINE

RECORDING RATE

XXHR EVERY XXSEC

TEMPERATURE

TO FAHRENHEIT

PUSH MENU TO RUN

OTHERS TO PRINT

READ RECORDED

DATA FROM SCREEN

SEND OUT ALL OF

THE TEMP DATA

Summary of Contents for OM-60-MOD-TE

Page 1: ...D TE cables by the user is not recommended and will void the sensor warranty The voltage detector is connected by two coiled clip leads available at the interface box The voltage detector will operate...

Page 2: ...s not connected or has become defective the display will indicate that the sensor is not responding Temperature sensor is not responding CHANGING SETTINGS Every function of the Service Logger can be s...

Page 3: ...r and event detector but will only record data on a change in the state of the event detector When the M ENU EN TER button is pressed 3 more times to cycle through the remaining functions the recordin...

Page 4: ...ding prior to starting a new recording The first step in making a recording is to select the proper recording time and sample rate If a sampling rate of 15 seconds is being used then every 15 seconds...

Page 5: ...minate recording if the Service Logger was set to record previously 3 Record information to memory and to a printer This is a combination of options 1 and 2 Information is stored in memory and at the...

Page 6: ...the upper right hand corner of the display The R indicates recording is in progress While you are recording it is possible to check how much memory has been used Press and hold the STA TU S button unt...

Page 7: ...s is that data samples that are less than the selected temp erature change or if the state of the event detector stays the same no samples will be printed until the conditions that are programmed in t...

Page 8: ...he temperature continued to decrease with the fan OFF at 5 32 a m on the Tuesday of the same week End of Data This indicates the end of the recording and shows that the temperature remained within 2 o...

Page 9: ...to operate an error message will be displayed to alert the user to a printer problem There are several possible problems that may occur if the printer is not ready The Service Logger will alert the u...

Page 10: ...have to manually scan a potential 4000 data samples to find the information of interest Press and hold M ENU EN TER until this display appears The actual recording rate is unimportant Press M ENU EN...

Page 11: ...g of the data recording or R EC O R D to go to the last previous data sample Press M ENU EN TER at any time to return to the Operating Mode TRANSFERRING DATA TO A COMPUTER After a recording has been m...

Page 12: ...puter screen A README file is also included on the floppy diskette which has detailed instructions on the use of the transfer program and reflects the latest information that is not included in this m...

Reviews: