6
APPLIANCE GAS CONNECTION
IMPORTANT:
This appliance must be installed by an authorised person.
WARNING:
The appliance utilises a threaded 1/2" gas male fitting.
WARNING:
DO NOT MODIFY THIS APPLIANCE
To connect the appliance to the gas network with a flexible rubber hose, a supplemental hose nipple fitting is needed
(Fig. 6) which is supplied with the appliance.
Gas Regulator
The gas connection is via 1/2" compression. Connect the cooker to the gas supply and check for gas soundness.
Natural Gas
: Gas regulator supplied with the appliance must be installed.
LPG
: Test point adaptor to be fitted and checked at time of installation.
If using a flexible connection
This appliance is approved for connection with a flexible hose, which complies with the AS/NZS 1869 (AGA Approved),
10mm ID, class B or D, between 1-1.2m long.
Connection shall be in compliance with AS5601.
When installing the hose restraint device, the appliance anchor point is the rear panel securing
.
Gas connection
The cooker must be connected to the gas supply with upstream connection of an isolation valve in accordance with
the respectively valid regulations. We recommend that the isolation valve be fitted prior to the cooker to enable
isolation of the cooker from the gas supply. The valve must be easily accessible at all times
To find out the factory set gas type, see label at rear of cooker
The gas connection is via 1/2" compression. Connect the cooker to the gas supply and check for gas soundness.
NEVER use a naked flame to check for gas leaks.
Gas inlet (mm)- Nat gas Gas inlet (mm)- LPG
From RH rear side: 35 mm From RH rear side: 35mm
Up from floor: 590 mm
Up from floor: 675 mm