APPLIANCE ELECTRICAL CONNECTION
The electric connection must comply with the current legal standards and regulations.
Before making the connection, check that:
The system electrical rating and the current outlets are adequate for the maximum power output of the
appliance (see the label applied to the bottom of the casing).
The outlet or the system is equipped with an efficient ground connection in accordance with the current legal
standards and regulations. The manufacturer will not be responsible for the non-compliance with these
instructions.
The power cord is supplied with a 15A plug, suitable for the load indicated on the label and a standard 15A
GPO.
Letter L (phase) = brown wire;
Letter N (neutral) = blue wire;
Ground symbol
= green-yellow
wire;
Fig. 17
The power cord must be positioned so that a
temperature of 75°C
will not be reached at any point.
Do not use reductions, adapters or splitters since they might cause false contacts and lead to dangerous
overheating.
When the connection is made directly to the electric network:
Use a device that ensures disconnection from the mains in which the contacts are opened to a distance that
permits complete disconnection according to the conditions for over-voltage category III.
Remember that the ground wire must not be interrupted by the circuit-breaker.
As an alternative, the electric connection can also be protected by a high-sensitivity residual current circuit-
breaker but this may be subject to nuisance tripping due to residual humidity in heating elements.
It is highly recommended to attach the special green-yellow ground wire to an efficient ground system.
WARNING:
If the power cord is replaced, the ground wire (yellow-green) connected to the terminal, should
be longer than the other wires by about 2 cm.
WARNING:
If the supply cord is damaged, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard.
TABLE N°4
: TYPES OF POWER CORDS
Work surface
operation
Oven
operation
Cross section
230V ~
230V 3~
400V 2N~
400V 3N~
Only gas burner
Gas oven / Gas grill
3x0.75mm²
-
-
-
Gas oven / Electric grill
3x1mm²
-
-
-
Electric Oven
3x1mm² (MH)
3x1,5mm² (MX M9)
-
-
-
Ventilated Electric Oven
3x1,5mm²
-
-
-
Gas burner + 1 hot plate
Gas oven / Gas grill
3x1mm²
-
-
-
Gas oven / Electric grill
3x1,5mm² (MH)
3x2,5mm² (MX /M9)
-
-
-
Electric Oven
3x1,5mm² (MH)
3x2,5mm² (MX /M9)
-
-
-
Ventilated Electric Oven
3x2,5mm²
-
-
-
Gas burner + 2 hot plate
Electric Oven
3x2,5mm²
4x1,5mm²
4x1,5mm²
5x1,5mm²
Ventilated Electric Oven
3x2,5mm²
4x1,5mm²
4x1,5mm²
5x1,5mm²
4 hot plate
Electric Oven
3x2,5mm²
4x1,5mm²
4x1,5mm²
5x1,5mm²
Ventilated Electric Oven
3x2,5mm²
4x1,5mm²
4x1,5mm²
5x1,5mm²
Ceran
Electric Oven
3x2,5mm²
4x1,5mm²
4x1,5mm²
5x1,5mm²
Ventilated Electric Oven
3x4mm²
4x1,5mm²
4x1,5mm²
5x1,5mm²
ATTENTION: The appliance conforms with the regulations of directives 90/396EEC (Gas Directive) regarding gas
appliances for domestic use and the like, 93/68 and 73/23 (Low Voltage Directive) regarding electrical safety and
2004/108/CE, 93/68 and 89/336 (EMC Directive) regarding electromagnetic compatibility.