10
ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any maintenance operation, disconnect the appliance from the gas supply and electricity
network.
REPLACING THE NOZZLES TO OPERATE WITH ANOTHER TYPE OF GAS
When converting to LPG remove gas regulator if fitted and fit LPG test point adaptor.
If converting to Natural Gas, fit gas regulator
Follow the instructions below to change the burner nozzles on the work surface:
1) Pull out the plug from the electric outlet to avoid any type of electric contact.
2) Remove the grids from the work surface (Fig. 7A-7B).
3) Remove the burners (Fig. 7A-7B).
Fig. 7A
Fig.7B
4) Unscrew the nozzles using a 7 mm spanner, and replace them (Fig.8) with those needed for the new type of gas
according to what is indicated in Table 1 for model MH and in Table 2 for model MX M9.
Fig. 8
2) Burner "MINIMUM" adjustment:
Work surface burner adjustment
: follow the instructions below to adjust the work surface burner minimum:
1) Light the burner and set the knob to the MINIMUM position (small flame).
2) Remove the knob of the valve that is press fit on the rod of that valve.
3) If the cooker is not equipped with safety valves on the surface burners, insert a small slotted screwdriver into the hole
on the valve rod (Fig. 14) and turn the choke screw to the right or left until the burner flame is adjusted to minimum. If the
cooker is equipped with safety valves, the choke valve is not located in the rod hole but on the valve body (Fig. 15).
4) Ensure sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position.
Fig. 14
Fig. 15