OMEGA AUTOMATICS 2020 v3.0.2
25
16. Programming encoder and parameters
Install the operator based on the following instructions and use the required tools.
✓
Make sure door is in full closed position
✓
Menu
Calibrate display will indicate push ACT begin
✓
Press ACT touch button
✓
Manually push the fully open position, release the door to fully close and press SEL
✓
Set up the parameters following basic set up instructions
✓
Activate the door operator to perform learning cycle
❖
V2.3 beta-HD only
ACT DLY- Changed to delay between electric strike and door operator
Pre-load time- time now long will the door operator reverse before opening to release pressure on strike (used only HD)
Preload speed- Speed /force under which the door operator will reverse before opening to release pressure on strike (use
only on HD)