Refer to table for setting parameters.
Parameter
7’-8’ door
8’-10’
10’+
Overload
55-65
65-85
HD
Act Delay
0-2
0-2
HD
Backcheck speed
20-22
20-24
HD
Holding time
˃5
˃5
HD
Opening speed
50-55
50-55
HD
Closing speed
35-50
35-50
HD
Latch speed
1-5
1-5
HD
Hold open
0-OFF 1-ON
0-OFF 1-ON
HD
Power assist
0-OFF 1-ON
0-OFF 1-ON
/
Reactivate
0-OFF 1-ON
0-OFF 1-ON
/
✓
Once parameters are set the door operator is ready for learning cycle.
✓
Check the doorway for any obstacles and make sure that the door close and open smoothly.
✓
Check if the door is fully closed and display shows door closed press the ACT touch button.
Fig 7.5.5
✓
The display will show “door opening”.
Door closed