OMEGA AUTOMATICS 2020 v3.0.2
18
Fig 7.5.6
✓
The learning cycle does not register obstruction. Make sure that the path of the door is clear from obstacles.
✓
Once the learning cycle is completed and the door is in closed position the door operator is programmed.
✓
Connect activating device and run multiple test cycle to assure proper operation.
7.6 Programming Heavy Duty (XP) operators
✓
After you follow the abovementioned steps of installation of the push or pull arm application, turn on the operator
then control board should recognize the encoder.
✓
Press MENU touch button then press down touch button to see “Calibrate”.
Fig 7.6.1
✓
Then press the SEL touch button.
✓
Screen shows “Hit ACT to begin”.
✓
Press ACT button and manually push the door to the maximum opening position.
Door Opening
[Learning]
Calibrate